REU-2532W Series
40
Rinnai
4) Is the combustion fan motor normal ?
Motor check.
If error “61” is displayed, check the combustion
fan.
a.
Measure voltage at connector A
1.
Black and red
wires.
Normal:
6 ~ 45 VDC (Fan on)
0 VDC (Fan off)
If normal, check item b below.
Faulty:
Replace the PCB unit.
Fan revolution sensor check.
b.
Measure voltage at connector A
1,
black and
yellow wires.
Normal:
11 ~ 13 VDC or 3.1 ~ 3.7 K
Ω
If normal, check item c below.
Faulty:
Replace the PCB unit.
c.
Measure voltage at connector A
1,
black and
white wires.
Normal:
6 ~ 45 VDC or 9 ~ 9.4 K
Ω
(33 ~ 400 Hz.)
If normal, proceed to check item 5 below.
Faulty:
Replace the combustion fan motor.
5) Is the sparker operating normally ?
Check the sparker module.
a.
Measure voltage at connector F
8,
grey and grey
wires.
Normal:
90 ~ 110 VAC
0 VDC (when fan is off)
If normal, check b below.
Faulty:
Replace the PCB unit.
b.
# Disconnect connector F
8,
and measure the
resistance between the two sparker terminals.
Normal:
> 1 M
Ω
Faulty:
Replace the igniter module.
Electrode gap should be
3
/
16
” to
1
/
4
” .
.
Summary of Contents for Continuum REU2532-W Series
Page 8: ...REU 2532W Series 8 Rinnai 3 Dimensions...
Page 9: ...REU 2532W Series 9 Rinnai 4 Installation Piping recommendation...
Page 16: ...REU 2532W Series 16 Rinnai 9 Cut way Diagram REU 2532 FFU Series...
Page 17: ...REU 2532W Series 17 Rinnai 10 Schematic Diagram REU 2532W Series...
Page 26: ...REU 2532W Series 26 Rinnai 15 Time Charts External Unit...
Page 27: ...REU 2532W Series 27 Rinnai...
Page 35: ...REU 2532W Series 35 Rinnai 20 REU 2532W Series Wiring...
Page 36: ...REU 2532W Series 36 Rinnai 21 Block Diagram...
Page 60: ...REU 2532W Series 60 Rinnai 26 EXPLODED VIEW CABINET...
Page 61: ...REU 2532W Series 61 Rinnai EXPLODED VIEW INTERNALS...
Page 62: ...REU 2532W Series 62 Rinnai EXPLODED VIEW INTERNALS...
Page 63: ...REU 2532W Series 63 Rinnai EXPLODED VIEW ELECTRICAL...