REU-2532W Series
47
Rinnai
23.
ELECTRICAL COMPONENT ANALYSIS
Nature of Fault
Examination Point
Diagnostic Point
Values
Y/N
Action
Repair
N
o
Yes
Go to A – (2)
1. Do you have
voltage to the unit?
Inspect visually
Do you have 120 VAC
at the power supply?
No Plug
in
cord
1
Yes
Go to A – (3)
2. Is supply voltage
correct?
Measure voltage at power
point.
120 VAC
No Check
power
supply circuit.
Check fuses.
2
Yes
Go to A – (4)
3. Check surge
protector.
Inspect visually
Do you have 120 volts
AC across the blue
and brown wires at the
surge protector?
No
Go to A – (5)
Yes
Go to A – (5)
and replace
fuse.
4. Check 3 amp
electrical fuses.
# Disconnect and measure
resistance to confirm if
fuse is blown. Normal <
than 1M
Ω
Is fuse blown.
No
Go to A – (6)
Yes
Go to A – (6) -
2
1. Measure resistance of
each solenoid valve.
# Remove connector E
from the PCB before
measuring .
Pink ~ Black (SV0)
1.7 ~ 2.1K
Ω
Yellow ~ Black (SV1)
1.7 ~ 2.1K
Ω
Brown ~ Black (SV2)
1.7 ~ 2.1K
Ω
Are valves within
those specified at left?
# Measure after
checking that there are
no broken wires or
shorts.
No Replace
faulty
solenoid
valves.
3
Yes
Go to A (5-3)
1.
Measure the
resistance.
# Disconnect sparker
connector F
8
and measure
the resistance between both
terminals.
Is resistance
>
1M
Ω
?
No Replace
sparker.
4
Yes Rectify/
Replace
5
5. Check for short
circuits.
3. Check wiring.
Are there any shorts ?
No Replace
PCB
6
Yes
Go to A (6-2)
A. The LED on
the remote
control does not
light up, when
the system is
powered up
6. Check to ensure
you have 120 VAC
across both terminals
feeding the surge
protector.
1. Measure voltage at the
blue and brown or black
and white wires.
100 ~ 120 VAC
No Check
for
proper voltage
to unit.
Summary of Contents for Continuum REU2532-W Series
Page 8: ...REU 2532W Series 8 Rinnai 3 Dimensions...
Page 9: ...REU 2532W Series 9 Rinnai 4 Installation Piping recommendation...
Page 16: ...REU 2532W Series 16 Rinnai 9 Cut way Diagram REU 2532 FFU Series...
Page 17: ...REU 2532W Series 17 Rinnai 10 Schematic Diagram REU 2532W Series...
Page 26: ...REU 2532W Series 26 Rinnai 15 Time Charts External Unit...
Page 27: ...REU 2532W Series 27 Rinnai...
Page 35: ...REU 2532W Series 35 Rinnai 20 REU 2532W Series Wiring...
Page 36: ...REU 2532W Series 36 Rinnai 21 Block Diagram...
Page 60: ...REU 2532W Series 60 Rinnai 26 EXPLODED VIEW CABINET...
Page 61: ...REU 2532W Series 61 Rinnai EXPLODED VIEW INTERNALS...
Page 62: ...REU 2532W Series 62 Rinnai EXPLODED VIEW INTERNALS...
Page 63: ...REU 2532W Series 63 Rinnai EXPLODED VIEW ELECTRICAL...