REU-2532W Series
37
Rinnai
22.
Electrical Component Analysis
Before carrying out checks marked with a # sign, disconnect power supply.
Unit’s wiring diagram can be found on page 35.
Appliance fails to operate (even remote control fails to operate).
1) Is the fuse blown
Fuses are located in plastic
holders in the main harness,
on the lower right hand side
of the appliance.
Check fuse.
a.
Disconnect unit from power supply.
b.
# Measure resistance to check the electric fuse (3
amp)
Normal:
less than 1
Ω
If normal, proceed to check item 2 below.
Faulty:
Replace 3 amp glass fuse. If the fuse
blows again, investigate cause of short
circuit.
2) Is the main transformer normal ?
Check the transformer.
a.
Measure the voltage and/or resistance at
connector F, black ~ white wires.
Normal:
100 ~ 120 VAC
51 ~ 63
Ω
resistance
Faulty:
Check for 120 – 125 VAC at the surge
p
rotector, blue ~ brown wires, connector
F
7
.
Resistance reading 51 ~ 63
Ω
If normal, check item 3 on next page.
Faulty:
Replace the transformer.
Summary of Contents for Continuum REU2532-W Series
Page 8: ...REU 2532W Series 8 Rinnai 3 Dimensions...
Page 9: ...REU 2532W Series 9 Rinnai 4 Installation Piping recommendation...
Page 16: ...REU 2532W Series 16 Rinnai 9 Cut way Diagram REU 2532 FFU Series...
Page 17: ...REU 2532W Series 17 Rinnai 10 Schematic Diagram REU 2532W Series...
Page 26: ...REU 2532W Series 26 Rinnai 15 Time Charts External Unit...
Page 27: ...REU 2532W Series 27 Rinnai...
Page 35: ...REU 2532W Series 35 Rinnai 20 REU 2532W Series Wiring...
Page 36: ...REU 2532W Series 36 Rinnai 21 Block Diagram...
Page 60: ...REU 2532W Series 60 Rinnai 26 EXPLODED VIEW CABINET...
Page 61: ...REU 2532W Series 61 Rinnai EXPLODED VIEW INTERNALS...
Page 62: ...REU 2532W Series 62 Rinnai EXPLODED VIEW INTERNALS...
Page 63: ...REU 2532W Series 63 Rinnai EXPLODED VIEW ELECTRICAL...