7.
Safety Devices
Flame Failure
Situated to the right of the burner in the front of the combustion chamber, the flame rod monitors the
combustion process. This sensor monitors the flame intensity, while the PCB compares this signal to the
feed back signal from the combustion fan motor, water flow control, and gas flow through the POV
valve. If any one of the feedback signals are incorrect, the unit will shut off, preventing discharge of
gas to the burner.
Over Heat Protection Device
Also referred to as an Over Heat Switch. This device is fitted to a bend section at the left side of the heat
exchanger. If the flame remains on to the burner after the tap is closed and the water temperature inside
the heat exchanger reaches 194 ° F, a 12 volt DC bi-metal cut-off switch will shut off the gas supply to
the solenoids.
No Water
Should the incoming water flow become restricted or stop, the water flow sensor will cease to send a
magnetic pulse signal to the PCB, in turn preventing gas to flow into the combustion chamber. If you
have restricted flow, first check to ensure the inline water filter is not clogged up.
Thermal Fuse
Wrapped around the entire surface of the heat exchanger you will find a thermal fuse. This device
activates in the event the heat exchanger burns out, or the temperature outside the heat exchanger
reaches 264 °F. If the thermal fuse melts, it breaks an electronic circuit which in turn shuts off the
power supply to the gas solenoids, shutting the unit off.
Combustion Fan Revolution Check
The combustion fan rpm’s are continually monitored by a magnetic pulse generator connected to the
PCB. If the fan revolutions deviate from the speed required for complete combustion, a signal is sent to
the PCB and the revolutions adjust accordingly. (If not the unit shuts down)
Automatic Frost Protection
When the temperature inside the appliance drops below 37 °F , the frost sensing device inside the
appliance activates the anti-frost heaters to prevent the water inside the unit from freezing. The anti-
frost heaters remain ON until the temperature inside the appliance rises to 57 °F. There are five (16) watt
anti-frost heaters located at various points throughout the main water flow area of the appliance. The
unit also incorporates the ability to fire for (3) seconds in the event the anti-frost heaters can not keep
the water temperature from dropping below 37 °F. This unique feature will heat the water in the lines
inside the appliance back up to 57 °F
. Both of the above features function as long as the unit has
power and gas.
There is an optional freeze protection system that can be added to the unit’s piping. See
the auto drain down drawing in the product Owner’s manual for instructions on how to install the option
freeze protection in the event of a power failure in cold climates.
Summary of Contents for Continuum REU2532-W Series
Page 8: ...REU 2532W Series 8 Rinnai 3 Dimensions...
Page 9: ...REU 2532W Series 9 Rinnai 4 Installation Piping recommendation...
Page 16: ...REU 2532W Series 16 Rinnai 9 Cut way Diagram REU 2532 FFU Series...
Page 17: ...REU 2532W Series 17 Rinnai 10 Schematic Diagram REU 2532W Series...
Page 26: ...REU 2532W Series 26 Rinnai 15 Time Charts External Unit...
Page 27: ...REU 2532W Series 27 Rinnai...
Page 35: ...REU 2532W Series 35 Rinnai 20 REU 2532W Series Wiring...
Page 36: ...REU 2532W Series 36 Rinnai 21 Block Diagram...
Page 60: ...REU 2532W Series 60 Rinnai 26 EXPLODED VIEW CABINET...
Page 61: ...REU 2532W Series 61 Rinnai EXPLODED VIEW INTERNALS...
Page 62: ...REU 2532W Series 62 Rinnai EXPLODED VIEW INTERNALS...
Page 63: ...REU 2532W Series 63 Rinnai EXPLODED VIEW ELECTRICAL...