![Rigol MSO8000 Series User Manual Download Page 329](http://html1.mh-extra.com/html/rigol/mso8000-series/mso8000-series_user-manual_1461151329.webp)
Chapter 18 Function/Arbitrary Waveform Generator (Option)
RIGOL
MSO8000 User Guide
18-17
➢
Log: the frequency of the signal changes in log form.
➢
Step: the frequency of the signal changes with ladder-like step.
2.
Sweep Settings
Press
Settings
to enter the sweep setting menu.
⚫
Set start frequency and end frequency
Start frequency and end frequency indicate the upper and lower limits of
the sweep frequency. The Function/Arbitrary Waveform Generator always
sweeps from the start frequency to the end frequency, and then returns
back to the start frequency.
➢
When start frequency is smaller than the end frequency, the
Function/Arbitrary Waveform Generator sweeps from low frequency to
high frequency.
➢
When start frequency is greater than the end frequency, the
Function/Arbitrary Waveform Generator sweeps from high frequency
to low frequency.
➢
When start frequency is equal to the end frequency, the
Function/Arbitrary Waveform Generator outputs at a fixed frequency.
Press
Start Freq
, then rotate the multifunction knob
or use the
pop-up numeric keypad to set the start frequency. Press
End Freq
, then
rotate the multifunction knob
or use the pop-up numeric keypad to set
the end frequency. By default, the start frequency is 100 Hz, and the end
frequency is 1 kHz. The ranges of start frequency and end frequency for
different sweep waveforms are different. After modifying the "Start Freq"
and "End Freq", the Function/Arbitrary Waveform Generator will restart to
output from the specified "Start Freq".
⚫
Start Keep
Start keep indicates the time that the output signal keeps outputting at the
"Start Freq" after the sweep starts. After the start keep time expires, the
Function/Arbitrary Waveform Generator will continue outputting at a
different frequency based on the current sweep type.
Press
Start Keep
, then rotate the multifunction knob
or use the
pop-up numeric keypad to set the start keep time. The default is 0 s, and
the range is from 0 s to 500 s.
⚫
End Keep
End keep indicates the time that the output signal continues outputting at
the "End Freq" after the Function/Arbitrary Waveform Generator sweeps
from "Start Freq" to "End Freq".
Press
End Keep
, then rotate the multifunction knob
or use the pop-up
numeric keypad to set the end keep time. The default is 0 s, and the range
is from 0 s to 500 s.
Summary of Contents for MSO8000 Series
Page 1: ...User Guide MSO8000 Series Digital Oscilloscope Mar 2021 RIGOL TECHNOLOGIES CO LTD...
Page 2: ......
Page 24: ......
Page 72: ......
Page 78: ......
Page 148: ......
Page 202: ......
Page 208: ......
Page 214: ......
Page 248: ...RIGOL Chapter 12 Protocol Decoding 12 14 MSO8000 User Guide...
Page 264: ...RIGOL Chapter 12 Protocol Decoding 12 30 MSO8000 User Guide Sync Error...
Page 284: ......
Page 290: ......
Page 296: ......
Page 302: ......
Page 308: ......
Page 360: ......
Page 383: ...Chapter 21 Remote Control RIGOL MSO8000 User Guide 21 3 5 6 3 4...
Page 394: ......