![Rigol MSO8000 Series User Manual Download Page 153](http://html1.mh-extra.com/html/rigol/mso8000-series/mso8000-series_user-manual_1461151153.webp)
Chapter 6 Operations and Measurements
RIGOL
MSO8000 User Guide
6-5
of Math3 can be CH1-CH4, Ref1-Ref10, Math1, or Math2; the source of
Math4 can be CH1-CH4, Ref1-Ref10, Math1, Math2, or Math3; only the
channels that have been enabled currently can be selected.
⚫
Press
Offset
to set the vertical offset of the operation results. For setting
methods, refer to the descriptions in "
". You can
also directly rotate
Wave Vertical
POSITION
or enable the touch screen
to adjust the vertical offset.
⚫
Press
Scale
to set the vertical scale of the operation results. For setting methods,
refer to the descriptions in "
". You can also
directly rotate
Wave Vertical
SCALE
or enable the touch screen to adjust
the vertical scale.
⚫
Press
More
→
AutoSetting
to adjust the vertical scale and offset of the
operation results to the optimal value according to the current configuration, so
as to better observe.
⚫
Press
More
→
Invert
to enable or disable the inverted display function of the
waveform.
⚫
Press
More
→
Expand
to expand or compress the measurement waveform
around the "Center" or "GND".
⚫
Press
More
→
Label
to set the label for math operation results. For details,
refer to descriptions in
.
⚫
Press
More
→
Color Grade
to enable or disable the color grade display of the
operation results. When enabled, different colors are displayed on the screen to
indicate the times of data acquisition or acquisition probability.
⚫
Press
More
→
Reset ColorGrade
to clear the color grade display and display
the color grade again.
Division
Divides the waveform voltage values of signal source A by that of source B point by
point and displays the results. It can be used to analyze the multiple relationships of
waveforms of two channels.
Note:
When the voltage of signal source B is 0 V, the division result is treated as 0.
Press
Math
→
Math1
→
Operator
to select "A÷ B":
⚫
Press
Operation
continuously to enable or disable the division operation
function.
⚫
Press
SourceA
and
SourceB
respectively, and rotate the multifunction knob
to select the channel for SourceA and Source B. Then press down the knob
to select the channel. You can also press
SourceA
and
SourceB
continuously
or enable the touch screen to select the channel. The available channels for
SourceA and SourceB are CH1-CH4 and Ref1-Ref10.
Note:
The source of Math2 can be CH1-CH4, Ref1-Ref10, or Math1; the source
Summary of Contents for MSO8000 Series
Page 1: ...User Guide MSO8000 Series Digital Oscilloscope Mar 2021 RIGOL TECHNOLOGIES CO LTD...
Page 2: ......
Page 24: ......
Page 72: ......
Page 78: ......
Page 148: ......
Page 202: ......
Page 208: ......
Page 214: ......
Page 248: ...RIGOL Chapter 12 Protocol Decoding 12 14 MSO8000 User Guide...
Page 264: ...RIGOL Chapter 12 Protocol Decoding 12 30 MSO8000 User Guide Sync Error...
Page 284: ......
Page 290: ......
Page 296: ......
Page 302: ......
Page 308: ......
Page 360: ......
Page 383: ...Chapter 21 Remote Control RIGOL MSO8000 User Guide 21 3 5 6 3 4...
Page 394: ......