Set the view type: Press
View
, then rotate the multifunction knob
to select the form of the event table to be viewed. Press down the knob
to select it. You can also press
View
continuously or enable the touch
screen to select it. The available choices include "Packets", "Details",
and "Payload". You can also tap "Packets", "Details", or "Payload" at
the top of the event table to select it.
If you select "Packets", the decoded data, time, and other information
are displayed in the event table. If you select "Details", the detailed
data in the specified row will be displayed in the event table. If "…"
appears in the row of data, it indicates that the decoded data are not
fully displayed. At this time, you can view the details in the "Packets"
view. If you select "Payload", all data in the specified column will be
displayed in the event table.
If "…" appears in the specified column of
data, it indicates that the decoded data are not fully displayed. At this
time, you can view the details in the "Packets" view.
➢
Export: If you select "Packets", you can export time and the
corresponding decoded data. Press
Export
, the save setting menu is
displayed. You can export the data table of the packets to the internal
or external USB storage device (when detected) in CSV format. For
detailed saving operation, refer to descriptions in
.
➢
Jump to: Set the operating status of the oscilloscope to "STOP". Then,
select the data of the specified time from the event table. Press
Jump
to
and the specified data waveforms are displayed in the center of the
screen.
➢
Decode: The setting of this menu enables you to quickly view the
corresponding event tables of four decode modules (Decode1,
Decode2, Decode3, and Decode4). Press
Decode
and rotate the
multifunction knob
to select a decode module, then press down
the knob to select it. You can also press
Decode
continuously or
enable the touch screen to select it.
6.
Interpret the decoded FlexRay frame data
⚫
TSS: transmission start sequence, displayed as a pink patch.
⚫
Sync Frame: displayed as a pink patch.
⚫
ID (Frame ID): expressed in Hex, displayed as a blue-green patch.
⚫
PL (Payload Length): expressed in Hex, displayed as a dark blue patch.
⚫
HCRC (Header Cyclic Redundancy Check): expressed in Hex, displayed as a
yellow-green patch. When CRC error occurs, it is displayed as a red patch.
⚫
CYC (Cycle Number): expressed in Hex, displayed as a light blue patch.
⚫
Data: Its display format is the same as that of the bus data (Hex, Dec, Bin,
or ASCII), displayed as a green patch.
⚫
TCRC (Tail Cyclic Redundancy Check): expressed in Hex, displayed as a
yellow-green patch. When CRC errors occur, it is displayed as a red patch.
Summary of Contents for MSO8000 Series
Page 1: ...User Guide MSO8000 Series Digital Oscilloscope Mar 2021 RIGOL TECHNOLOGIES CO LTD...
Page 2: ......
Page 24: ......
Page 72: ......
Page 78: ......
Page 148: ......
Page 202: ......
Page 208: ......
Page 214: ......
Page 248: ...RIGOL Chapter 12 Protocol Decoding 12 14 MSO8000 User Guide...
Page 264: ...RIGOL Chapter 12 Protocol Decoding 12 30 MSO8000 User Guide Sync Error...
Page 284: ......
Page 290: ......
Page 296: ......
Page 302: ......
Page 308: ......
Page 360: ......
Page 383: ...Chapter 21 Remote Control RIGOL MSO8000 User Guide 21 3 5 6 3 4...
Page 394: ......