RigMaster LG200 Installation Manual
Section 11
August 2010 RigMaster Power International Ltd LG200 Service Manual
11:2:3 AutoStart Features and Operation
AutoStart Time/Day Programming
–allows you to program a day and time
for the LG200 for the start automatically up to 7 days in advance. This feature
will run for three hours and shut down. At the end of the AutoStart program the
cabin controller will display the error code #10, “Run Timeout”; this is normal.
Set AutoStart Timer
The user can adjust the time and day for the next timed AutoStart event. (
SET
symbol is flashing and
TIME AUTOSTART
symbol is turned on during alarm
setup)
Press
AUTOSTART
button:
Time AutoStart
will scroll across the screen.
Press
SELECT
button to continue,
MODE
to exit.
Press LEFT or RIGHT scroll button to adjust
AutoStart hour
as required.
Press
SELECT
button
Continue to set the
AutoStart Minutes
and
am/pm
as you would set the clock.
Press
SELECT
button after each entry.
Press LEFT or RIGHT scroll button to adjust
AutoStart Day
as required.
Press
SELECT
button
Press LEFT or RIGHT scroll button to locate
On/Off
.
Press
SELECT
button to save settings or press
MODE
button to return to menu
without saving.
NOTE:
When enabled,
Time AutoStart
symbol will be flashing.
Automatic Temperature Control Start Up/Shut Down
-will start and stop the
LG200 to regulate the temperature giving you further fuel savings on extended
absences from the cab.
Set AutoStart Temperature Start-Up
Press
AUTOSTART
button twice:
Temp AutoStart
will scroll across the screen.
Press
SELECT
button to continue,
MODE
to exit.
Press LEFT or RIGHT scroll button to select mode of temperature control. Mode
options include
OFF, AUTO, HEAT or COOL only
.
Press
SELECT
button to continue,
MODE
to exit.
Press LEFT or RIGHT scroll button to select AutoStart temperature setpoint if
HEAT
or
COOL
have been selected.
NOTE
The AutoStart temperature range is between 32°F and 95°F.
Press
SELECT
button to save settings or press
MODE
to return to menu without
saving.