RigMaster LG200 Installation Manual
Safety
August 2010 RigMaster Power International Ltd LG200 Service Manual
1. Zero Energy State
ATTENTION: ZERO ENERGY STATE
To perform service, maintenance and repairs you
must
disconnect the LG200 from its
battery source. In the recommended installation configuration the LG200 shares the battery
bank with the vehicles main engine. Unplug the J1 harness at the power module before
disconnecting the battery cables. After disconnecting the battery cables, check the battery
posts inside the LG200 engine cabinet to confirm there is no voltage to the auxiliary power
unit (APU).
2. Safety Cover Switch
It is critical that this safety cover switch is never deactivated or bypassed. Failure to
comply may result in serious injury.
The safety cover switch is designed to prevent the LG200 from starting when the engine
cover is loose or has been removed. When the switch is in the closed position the cover
is down. When the switch is in the open position the cover has been removed or is loose.
The switch is located at the very top of the unit enclosure on the coolant tank mounting
bracket.
3.
AutoStart Automatic Start/Stop Feature
ATTENTION: AUTOSTART FEATURE
Remember that a properly functioning LG200 is capable of starting independently of
its operator. If the AutoStart feature is enabled, battery voltage, temperature and time
of day can all cause the LG200’s engine to start. Please see the cabin controller’s
operating instructions for further information on the AutoStart feature.
You must
deactivate this feature prior to refueling.
ATTENTION: SAFETY COVER SWITCH
Cover Safety Switch