RigMaster LG200 Installation Manual
Section 4
August 2010 RigMaster Power International Ltd LG200 Service Manual
4:1:0
Mounting the Control Panel
The ideal mounting location for the control
panel is at the head of the bed and about half
way between the floor and the ceiling. Make
sure that the chosen location is close enough
to the HVAC unit that the communication cab le
will reach the power module when completely
routed. Ensure that vented air does not
discharge directly on the controller as this will
cause it to register a false temperature reading. Once a location has been chosen it
is necessary to either route the cables behind a cabinet or wall, or surface run the
cable securing it to prevent damage. When routing the cables, avoid sharp edges
and protect the cable from damage with grommets and/or wire loom. See that the
bunk and cabinetry will not make contact with the control panel when folding.
Use some self-tapping screws to secure the mounting bracket to the wall. Take
your time to make sure it is level; the operator will look at their control panel
closely for many years. If the screws protrude through to the inside of a cabinet,
use a piece of fuel line or shrink tube to cover the tip (short bolts and cap nuts are
preferable in this situation). This will protect the operator’s hands from damage
when reaching into the cabinet.
Cabin Controller Mounting Bracket
UP
Route Wire This Side