Residence Condens KIS n
20
ENGLISH
21
DESCRIPTION
25 KIS n
30 KIS n
Boiler dimensions
Height
mm
780
780
Width
mm
400
400
Depth at casing
mm
358
358
Boiler weight
kg
39
40
Heating output
G20
G31
G20
G31
Heating air output
Nm
3
/h
24,298
24,819
30,372
31,024
Heating flue gases capacity
Nm
3
/h
26,304
26,370
32,880
32,963
Mass flue gas flow rate max. heating
gr/s
9,086
9,297
11,357
11,621
Mass flue gas flow rate min. heating
gr/s
2,726
2,789
2,726
2,789
DHW output
G20
G31
G20
G31
DHW air capacity
Nm
3
/h
30,372
31,024
36,447
37,228
DHW flue gas capacity
Nm
3
/h
32,880
32,963
39,456
39,555
Mass flue gas flow rate max. DHW
gr/s
11,357
11,621
13,629
13,946
Mass flue gas flow rate min. DHW
gr/s
2,726
2,789
2,726
2,789
Fan performance
Residual discharge head of concentric pipes 0,85 m
Pa
50
60
Residual discharge head of separate pipes 0.5 m
Pa
80
100
Residual discharge head of boiler without pipes
Pa
90
110
Concentric flue gas outlet pipes
Diameter
mm
60-100
60-100
Maximum length
m
7,85
7,85
Losses for a 45°/90° bend
m
1,3/1,6
1,3/1,6
Hole in wall (diameter)
mm
105
105
Concentric flue gas outlet pipes
Diameter
mm
80-125
80-125
Maximum length
m
14,85
14,85
Losses for a 45°/90° bend
m
1/1,5
1/1,5
Hole in wall (diameter)
mm
130
130
Twin flue gas outlet pipes
Diameter
mm
80
80
Maximum length
m
53+53
42+42
Losses for a 45°/90° bend
m
1/1,5
1/1,5
Installation B23P–B53P
Diameter
80
80
Maximum discharge length
mm
80
80
Collective smoke pipes under pressure (with specific accessory only)
Max pressure allowed in the smoke pipe when
installed with collective smoke pipes
Pa
50 (**)
50 (**)
NOx class
5
5
Emission values at max-min gas flow rate (***)
G20
G31
G20
G31
Maximum
CO s.a. lower than
ppm
160
160
190
200
CO
2
%
9,0
10,0
9,0
10,0
NOx s.a. lower than
ppm
40
40
40
40
Flue gas temperature
°C
63
63
65
67
Minimum
CO s.a. lower than
ppm
25
25
25
25
CO
2
%
9,0
10,0
9,0
10,0
NOx s.a. lower than
ppm
40
40
40
40
Flue gas temperature
°C
60
58
60
58
(**) Applicable with G20 gas only
(***) Check performed with concentric pipe Ø 60-100 - length 0.85m - water temperature 80-60°C
(+) The installation of this product is allowed only in the destination Countries contained in the data plate, regardless of the present translation
language.