TECHNICAL DATA
DESCRIPTION
25 KIS n
30 KIS n
Heating
Heat input
kW
20,00
25,00
kcal/h
17.200
21.500
Maximum heat output (80/60°C)
kW
19,64
24,48
kcal/h
16.890
21.049
Maximum heat output (50/30°C)
kW
21,14
26,50
kcal/h
18.180
22.790
Minimum heat input
kW
6,00
6,00
kcal/h
5.160
5.160
Minimum heat output (80/60°C)
kW
5,87
5,87
kcal/h
5.052
5.052
Minimum heat output (50/30°C)
kW
6,44
6,44
kcal/h
5.537
5.537
Domestic hot water Heat input
kW
25,00
30,00
kcal/h
21.500
25.800
Maximum heat output (*)
kW
25,00
30,00
kcal/h
21.500
25.800
Minimum heat input
kW
6,00
6,00
kcal/h
5.160
5.160
Minimum heat output (*)
kW
6,00
6,00
kcal/h
5.160
5.160
CH/DHW Heat input at minimum with
installation in smoke pipe
under
pressure
kW
6,00 (**)
6,00 (**)
(*) average value between various hot water operation conditions
Useful efficiency Pn max - Pn min (80°/60°)
%
98,2 - 97,9
97,9 - 97,9
Useful efficiency 30% (47° return)
%
103,4
103,5
Combustion efficiency
%
98,5
98,2
Useful efficiency Pn max - Pn min (50°/30°)
%
105,7 - 107,3
106,0 - 107,3
Useful efficiency 30% (30° return)
%
109,6
109,6
Electric power (DHW)
W
88
102
Electric power (CH)
W
79
88
Maximum circulator electric power (1.000 l/h)
W
51
51
Category
II2H3P
II2H3P
Country of destination
(+)
(+)
Power supply voltage
V - Hz
230-50
230-50
Protection level
IP
X5D
X5D
Stop loss
W
45
45
Nominal chimney and skirt losses with burner off
%
0,14
0,11
Nominal chimney and skirt losses with burner on
%
1,48
1,81
Nominal chimney and skirt losses with burner on at minimum
%
1,16
1,16
Nominal losses through the casing with burner on
%
0,32
0,29
CH operation
Pressure - maximum temperature
bar-°C
3-90
3-90
Minimum pressure for standard operation
bar
0,25-0,45
0,25-0,45
Selection field of the heating water temperature
°C
20/45 ÷ 40/80
20/45 ÷ 40/80
Pump: maximum head available
mbar
326
326
for system capacity
l/h
1.000
1.000
Membrane expansion tank
l
8
9
Expansion tank pre-charge
bar
1
1
DHW operation
Maximum pressure
bar
6
6
Minimum pressure
bar
0,2
0,2
Hot water quantity
with ∆t 25°C
l/min
14,3
17,2
with ∆t 30°C
l/min
11,9
14,3
with ∆t 35°C
l/min
10,2
12,3
DHW minimum capacity
l/min
2
2
Selection field of the domestic hot water temperature
°C
35-60
35-60
Flow regulator
l/min
11
13
Gas pressure
G20
G31
G20
G31
Nominal gas pressure
mbar
20
37
20
37
Hydraulic connections
CH input - output
Ø
3/4”
3/4”
DHW input-output
Ø
1/2”
1/2”
Gas input
Ø
3/4”
3/4”