background image

4

GENERAL INFORMATION

GENERAL INFORMATION

DESCRIPTION OF THE APPLIANCE

R

 

RBS 2S Ready-i

 double-coil solar heaters, with pre-fitted 

vertical solar station, are available in four different models, and 

can be integrated in solar systems for the production of domes-

tic hot water.

The most important technical features of these solar storage cyl-

inders are:

 

− the accurate study of tank and coil geometry

 

− internal glazing, bacteriologically inert, to ensure the 

max. hygiene of treated water, reduce limescale deposits 

and make cleaning operations easier

 

− insulation made of expanded polyurethane free from CFC 

(chlorofluorocarbons)

 

− a flange for easy cleaning and maintenance of the an-

ti-corrosion magnesium anode

 

− solar station enclosed in a panelling, used also for solar 

system washing, filling and emptying as well as for cir-

culator removal

The main components of the solar station are:

 

− high-efficiency  circulator  with  variable  speed  (already 

hard-wired)

 

− solar regulator (already hard-wired), as indicated in par-

agraph "Safety and control devices"

 

− shut-off valves as non-return valves

 

− thermometers

 

− pressure gauge

 

− fitting for connection to a solar expansion tank

 

− suitable safety device, as indicated in paragraph "Safety 

and control devices"

SAFETY AND CONTROL DEVICES

Equipment safety and setting are achieved thanks to:

 

− Safety valve with trigger pressure set at 6 bar;

 

− Solar Regulator for circulator management/control. Man-

ages 9 system diagrams that can be selected. Refer to the 

specific manual for further details.

IDENTIFICATION

The 

R

 

RBS 2S Ready-i

 solar heaters can be identified by:

Data plate

This lists the technical specifications and performance of the 

product.

Model

bar

W

l

W

kW

l/1'

BOLLITORE SOLARE

Modello

Matricola

Codice

Anno

m

2

m

2

kW

m

2

T067765IES

SOLARBOILER

Serial numb.

Code

Year

Dispersioni secondo EN 12897

Heat loss according to EN 12897

V-Hz

Alimentazione elettrica

Power supply

Matricola

Serial number

Modello

Model

Potenza elettrica assorbita

Electrical consumption

Capacità del bollitore

Storage cylinder capacity

Press. esercizio max.

Maximum working pressure of storage cylinder

Superficie serpentino inferiore

Bottom coil heat exchange surface area

Superficie serp. inf.

Bottom coil heat exch.

Superficie serpentino superiore

Top coil heat exchange surface area

Produzione acqua calda sanitaria - serp. sup. [∆T 35°C]

Domestic hot water production – top coil [∆T 35°C]

Massima potenza assorbita sup. [T° Primario 80°C]

Power absorbed by top coil [T° primary 80°C]

Max pot. assorb. sup.

Power abs. by top coil

Collegamento di terra obbligatorio -

Connexión a tierra obligatoria 

Obligatory ground connection

RIELLO S.p.A.

Via Ing.Pilade Riello 7

37045  Legnago (VR) - ITALY

RIELLO S.p.A.

Via Ing.Pilade Riello 7

37045  Legnago (VR) - ITALY

Modelo

Código

N° Fabric.

Año

Potencia absor bida max.se rp.sup. [T° Pri mário 80°C]

Producción de agua caliente sanitaria - serp. sup. [∆T 35°C]

Superficie serpentín superior

Superficie serpentín inferior

Presión máxima de fun cio namiento

Capacidad del interacumulador

Potencia eléctrica 

absorbida

Alimentación eléctrica

Dispersiones según EN 12897

N° Fabric.

Modelo

Pot. absor. max.serp.sup.

Sup. serpentín inf.

INTERACUMULADOR SOLAR

surf. area

Serial number plate

This specifies the serial number and model.

 

9

If these plates or any other means of clearly identifying 

the product are defaced, removed or lost, proper instal-

lation and servicing may be rendered difficult.

Summary of Contents for RBS 200 2S Ready-i

Page 1: ...cod 20122045 rev 1 03 2017 RBS 2S Ready i EN INSTALLATION OPERATION AND MAINTENANCE MANUAL...

Page 2: ...ISH CONTENTS The following symbols are used in this manual 9 9CAUTION Identifies actions that require caution and adequate preparation 0 0STOP Identifies actions that you MUST NOT do This manual Code...

Page 3: ...the product purchase documents to be presented to the R authorised Technical Assistance Service to request a service call under warranty 9 9Size the solar expansion tank so as to ensure complete ab s...

Page 4: ...te This lists the technical specifications and performance of the product Model bar W l W kW l 1 BOLLITORE SOLARE Modello Matricola Codice Anno m2 m2 kW m2 T067765IES SOLARBOILER Serial numb Code Year...

Page 5: ...6 bar 14 Tap A for system filling draining 15 Tap B for system filling draining 16 Delivery Valve solar plant delivery with built in non return valve 17 Outlet temperature gauge 18 Return Valve solar...

Page 6: ...3 1 51 W K Energy class B B B B PERFORMANCE RELATING TO INTEGRATION COIL Upper coil continuous efficiency ACS 10 45 C Vbu reference volume Coil delivery temperature 80 C T 20 C 16 1 23 31 4 31 4 kW 40...

Page 7: ...tank lower part 70 C 374 438 659 863 l 60 C 284 375 531 675 l 50 C 205 310 390 485 l DESCRIPTION SOLAR STATION TECHNICAL DATA Safety valve calibration pressure 6 bar Maximum operating temperature 110...

Page 8: ...than IP X0D 0 3 m 0 6 m 0 3 m 0 6 m 0 7 m NOTE the above indicated dimensions are recommended for a correct maintenance and access to the device 9 9When installing the boiler allow sufficient space ar...

Page 9: ...1 33 450 1 33 450 1 33 520 1 33 520 mm DF Flange internal diameter 130 130 130 130 mm A 1338 1838 1644 1988 mm B 1170 1670 1440 1784 mm C 1098 1438 1289 1653 mm D 953 1233 1064 1428 mm F 598 693 684 7...

Page 10: ...revailing standards of the installation country respect the polarity of the L1 Phase N Neutral con nections use cables with insulation and cross section conforming to applicable standards minimum cros...

Page 11: ...to terminal board M1 of solar regulator terminals L N GND making refer ence to the instructions provided in the specific regulator manual Once electrical connections are completed fasten cables using...

Page 12: ...r collectors For further information please refer to the glycol safety data sheet When using glycol not pre mixed Do NOT part fill the circuit with pure glycol then add water later Ensure that filling...

Page 13: ...ressure To set the system pressure correctly refer to the design manual 0 0Do not fill the system in bright sunny conditions or if the collectors are hot 9 9Use a manual bleed valve which should be in...

Page 14: ...20 3 Safety valve removal 9 9Remove when system has cooled down Before removing the safety valve Cut power off to the solar station and to the connected integration system by setting the system s mai...

Page 15: ...with the product 23 TEMPORARY SHUTDOWN To reduce to the environmental impact and save energy in case of brief absences week ends short trips etc and with exter nal temperatures above 0 C set the heat...

Page 16: ...lo 7 37045 Legnago VR www riello com The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liabl...

Reviews: