UNPACKING THE PRODUCT

R

 

RBS 2S Ready-i

 solar heaters are supplied in a single pack-

age on a wooden pallet.

The boiler comes with a solar station supplied with solar reg-

ulator already wired to the high-efficiency circulator, and two 

non-wired probes to be inserted in the boiler sockets.

The following items are delivered in a plastic bag inside the 

packaging:

 

− Instruction manuals

 

− Bar code label

 

− Hydraulic test certificate

 

− Energy label (to be applied to device upon installation)

 

− No. 1 solar probe PT1000.

 

9

The instruction manual is an integral part of the solar stor-

age cylinder. Once located, read it thoroughly and keep it 

safe.

 

9

For handling operations, thoroughly follow the instructions 

on device package label.

ACCESS TO THE SOLAR STATION

To access the solar station it is necessary to remove the front 

panel (1) by pulling it towards yourself and lifting it up by means 

of the specific handles.

1

Locate the bag containing the documentation, remove the en-

ergy label and apply it to the boiler casing

Installation

10 

PLACE OF INSTALLATION

R

 

RBS 2S Ready-i

 storage cylinders can be installed in any 

room where there is no specific requirement for an electrical 

protection rating higher than IP X0D.

≥ 0,3 m

≥ 0,6 m

≥ 0,3 m

≥ 0,6 m

≥ 0,7 m

NOTE:

 the above-indicated dimensions are recommended for a 

correct maintenance and access to the device.

 

9

When installing the boiler, allow sufficient space around it 

to access all safety and control devices and to permit easy 

maintenance.

11 

INSTALLATION IN OLDER SYSTEMS AND SYSTEMS 
REQUIRING MODERNISATION

When installing 

R

 

RBS 2S Ready-i

 storage cylinders in old sys-

tems or systems requiring modernisation, always perform the 

following checks.

 

− Make sure that the system is fitted with safety and con-

trol devices in accordance with applicable legislation and 

standards

 

− Make sure that the central heating circuit has been 

flushed out to remove all sludge and lime scale, and has 

been vented and seal tested

 

− Make sure that a suitable water treatment system is in-

stalled if the quality of the supply/recirculation water so 

demands (refer to the reference values listed in the table 

alongside).

12 

WATER QUALITY REQUIREMENTS

REFERENCE VALUES

pH

6-8

Electrical conductivity

less than 200 μS/cm (25°C)

Chlorine ions

less than 50 ppm

Sulphuric acid ions

less than 50 ppm

Total iron

less than 0.3 ppm

Alkalinity M

less than 50 ppm

Total hardness

less than 35°F

Sulphur ions

none

Ammonia ions

none

Silicon ions

less than 30 ppm

The values above ensure proper operation of the system. Refer 

to the limit values specified in the current standards and regu-

lations on the installation site.

Summary of Contents for RBS 200 2S Ready-i

Page 1: ...cod 20122045 rev 1 03 2017 RBS 2S Ready i EN INSTALLATION OPERATION AND MAINTENANCE MANUAL...

Page 2: ...ISH CONTENTS The following symbols are used in this manual 9 9CAUTION Identifies actions that require caution and adequate preparation 0 0STOP Identifies actions that you MUST NOT do This manual Code...

Page 3: ...the product purchase documents to be presented to the R authorised Technical Assistance Service to request a service call under warranty 9 9Size the solar expansion tank so as to ensure complete ab s...

Page 4: ...te This lists the technical specifications and performance of the product Model bar W l W kW l 1 BOLLITORE SOLARE Modello Matricola Codice Anno m2 m2 kW m2 T067765IES SOLARBOILER Serial numb Code Year...

Page 5: ...6 bar 14 Tap A for system filling draining 15 Tap B for system filling draining 16 Delivery Valve solar plant delivery with built in non return valve 17 Outlet temperature gauge 18 Return Valve solar...

Page 6: ...3 1 51 W K Energy class B B B B PERFORMANCE RELATING TO INTEGRATION COIL Upper coil continuous efficiency ACS 10 45 C Vbu reference volume Coil delivery temperature 80 C T 20 C 16 1 23 31 4 31 4 kW 40...

Page 7: ...tank lower part 70 C 374 438 659 863 l 60 C 284 375 531 675 l 50 C 205 310 390 485 l DESCRIPTION SOLAR STATION TECHNICAL DATA Safety valve calibration pressure 6 bar Maximum operating temperature 110...

Page 8: ...than IP X0D 0 3 m 0 6 m 0 3 m 0 6 m 0 7 m NOTE the above indicated dimensions are recommended for a correct maintenance and access to the device 9 9When installing the boiler allow sufficient space ar...

Page 9: ...1 33 450 1 33 450 1 33 520 1 33 520 mm DF Flange internal diameter 130 130 130 130 mm A 1338 1838 1644 1988 mm B 1170 1670 1440 1784 mm C 1098 1438 1289 1653 mm D 953 1233 1064 1428 mm F 598 693 684 7...

Page 10: ...revailing standards of the installation country respect the polarity of the L1 Phase N Neutral con nections use cables with insulation and cross section conforming to applicable standards minimum cros...

Page 11: ...to terminal board M1 of solar regulator terminals L N GND making refer ence to the instructions provided in the specific regulator manual Once electrical connections are completed fasten cables using...

Page 12: ...r collectors For further information please refer to the glycol safety data sheet When using glycol not pre mixed Do NOT part fill the circuit with pure glycol then add water later Ensure that filling...

Page 13: ...ressure To set the system pressure correctly refer to the design manual 0 0Do not fill the system in bright sunny conditions or if the collectors are hot 9 9Use a manual bleed valve which should be in...

Page 14: ...20 3 Safety valve removal 9 9Remove when system has cooled down Before removing the safety valve Cut power off to the solar station and to the connected integration system by setting the system s mai...

Page 15: ...with the product 23 TEMPORARY SHUTDOWN To reduce to the environmental impact and save energy in case of brief absences week ends short trips etc and with exter nal temperatures above 0 C set the heat...

Page 16: ...lo 7 37045 Legnago VR www riello com The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liabl...

Reviews: