LIMITED WARRANTY - TERMS AND CONDITIONS

10 

LIMITED WARRANTY - TERMS AND CONDITIONS

GENERAL NOTE

This limited warranty is provided by Riello Canada Inc. ("Riello") the 

following Riello products sold and installed in the United States and 

Canada:

Condexa PRO NA 75 P

Condexa PRO NA 117 P

This warranty is provided to the original purchaser as long as the 

boiler remains installed at its original place of installation. This 

warranty is provided in respect of the boiler heat exchanger and its 

insulation, casing and approved accessories designated by Riello.

The warranty is conditional upon:

 

− The  proper  installation  of  the  boiler  by  a  qualified  HVAC 

mechanical contractor or installer trained and certified in 

accordance with applicable laws and regulations of the ju-

risdiction in which the boiler is installed ("the Qualified Con-

tractor"); and

 

− Proper operation and maintenance of the boiler in accor-

dance with the boiler operation manual and service bulle-

tins as issued by Riello from time to time and the mandatory 

maintenance schedule provided in the Riello Installation & 

Operation Manual For Contractors.

Installation or maintenance of the boiler by a person other than a 

Qualified Contractor shall void this warranty.

Any component of a boiler returned to Riello in connection with this 

warranty agreement remains the property of Riello.

WARRANTY TERMS & CONDITIONS

PARTS WARRANTY

Riello warrants that the boilers and approved accessories designat-

ed by Riello shall be free of defects in manufacture, material and 

workmanship for 18 months from shipment or TWELVE (12) MONTHS 

from start-up (whichever comes first).

Furthermore, Riello will warrant parts for boilers mentioned in this 

certificate for an additional FOUR (4) YEARS bringing the total parts 

warranty to FIVE (5) YEARS provided the boiler is registered on the 

riello website, www.riello.com, within NINETY (90) DAYS.

The obligation of Riello under this warranty shall be to repair or 

replace those parts determined by Riello to be defective in material 

or workmanship.

This warranty is only in respect of boilers for which payment has 

been made in full.

TEN (10) YEAR WARRANTY OF PRIMARY and SECONDARY PLATE HEAT EX-

CHANGERS

Riello warrants that the heat exchanger(s) of the boiler shall be free 

from leakage, thermal shock and condensate corrosion, and shall 

be free from defects in material and workmanship for TEN (10) YEARS 

from the date of manufacture, which date is found within the boil-

ers serial number on the data plate so long as the boiler has been 

registered at www.riello.com.

The obligation of Riello under this ten year heat exchanger warranty 

shall be to repair or replace those parts of the heat exchanger de-

termined by Riello to be defective in material and workmanship in 

the heat exchanger as determined by Riello.

WARRANTY EXCLUSION

 

− If  the  boiler  is  not  installed  by  a  qualified,  Riello-trained 

heating contractor.

 

− Any costs for labor for the examination, removal or re-in-

stallation of allegedly defective Boiler parts, and transporta-

tion thereof to and from Riello facilities in North America or 

Italy, or as determined by Riello.

 

− Failures or malfunctions resulting from: Failure to properly 

install, operate or maintain the Boilers in accordance with 

our published Installation, Operation and Maintenance 

Manual or Users Information Manual provided with the 

product.

 

− Failure to install a low loss header or provide proper hydron-

ic separation where required.

 

− Damage to  the Boilers or any of its original or authorized 

replacement parts or other accessories designated by Riello 

as standard equipment caused by excessive temperatures 

or pressures, unsuitable fuels, fuel impurities, improper fuel 

mixture, fuel or gas explosion, electrical, chemical or elec-

trochemical reaction,  water impurities, unsuitable water 

conditions which may have caused unusual deposits within 

the water side and heat exchanger combustion area of the 

pressure vessel within the Boiler, water treatment chemicals, 

or water conditioning systems,  electrical failures, insurrec-

tion, riots, war, or acts of God, combustion air contaminated 

externally, air impurities, sulfur or sulphuric action or reac-

tion, dust particles, corrosive vapors, oxygen corrosion, and 

situating the Boiler in an  unsuitable location or continuing 

use of the Boiler after onset of a malfunction  or discovery 

of a defect.

 

− Deformation occurs due to freezing; improper storage or 

handling.

 

− If the appliance is not installed in accordance with all appli-

cable local and national codes and regulations.

 

− If the boiler is not installed in a clean, dry area.

 

− Any alterations are made without written authorization by 

the manufacturer.

Summary of Contents for Condexa PRO NA 117 P

Page 1: ...to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If yo...

Page 2: ...temperature relationships 16 4 14 Electronic control 17 4 14 1 Menu structure 18 4 14 2 Parameters list 24 4 15 Error List 25 4 15 1 Permanent Errors 25 4 15 2 Temporary Errors 25 4 15 3 Warnings 25...

Page 3: ...ded with this product as they will continually add fresh water to the system if there is a leak resulting in the addition of new con taminants that could reduce the lifespan of the boiler 9 9WARNING T...

Page 4: ...ON position 8 Turn on all electrical power to the appliance 9 Set thermostat to desired setting 10 If the appliance will not operate follow the instructions To Turn Off Gas To the Appliance and call y...

Page 5: ...stat Flow sensor capable of monitoring the main heating cir cuit s flow on an ongoing basis and of stopping the appli ance in the event of insufficient flow Temperature sensors on supply and return li...

Page 6: ...WCO Minimum Water Pressure Switch set to 7 psi 0 5 bar 10 Pump with integrated check valve 11 Power switch 12 Central heating return 13 Gas supply 14 Central heating supply 15 Condensate drain connect...

Page 7: ...re Switch set to 7 psi 0 5 bar 9 Pump with integrated check valve 10 Power switch 11 Central heating return 12 Gas supply 13 Central heating supply 14 Condensate drain connection 15 Flow meter 16 Gas...

Page 8: ...s after a safety lock out 3 MENU key switches on the main menu 4 ESC key in menu navigation it enables you to exit a menu item and go back to the previous one 5 9 Navigation keys 10 Power switch locat...

Page 9: ...thermostat to lowest setting Turn off all electric power to the appliance This appliance is equipped with an ignition device which automatically lights the burner Do not try to light the burner by han...

Page 10: ...e boiler in operation the ignition system safety shutoff device must be tested 4 8 Date and time setting Press the MENU button and select Settings with the buttons Menu Central Heating CH Information...

Page 11: ...s System Test Confirm with the button and select Boiler settings with the buttons Settings General Settings Boiler Settings Press the button to confirm The system will now ask you to enter a password...

Page 12: ...h heating mode Active for the heating mode Par 1 0 or 3 23 Limits the minimum value that can be assigned to the set point in heating mode does not apply to heating mode 4 24 Limits the maximum value t...

Page 13: ...mode and controlled by a room heat demand thermostat variable set point according to the outdoor tempera ture In this case the boiler operates with a set point defined by the climatic curve which can...

Page 14: ...Par 03 Setpoint TA OFF 9 9NOTE The outdoor temperature sensor sold as an accessory is not required and if connected the outdoor temperature that is measured does not influence the setpoint that has b...

Page 15: ...mum sanitary power 48 Establishes the DHW storage tank set point The setpoint value can be set directly without entering the list of parameters Press MENU and select Domestic Hot Water using the butto...

Page 16: ...H DHW and additional mixed zones Seasonal Program The seasonal program is used to exclude additional mixed zones during the summer season It does not control any DHW parameter 4 12 General Safety Info...

Page 17: ...back to the previous one 3 supports selecting menus or parameters or decreasing numeric values 4 enter 5 supports selecting menus or parameters or increasing nu meric values 6 supports moving to the...

Page 18: ...Supply Flowrate Failed Ignitions WW Shutdown Device Group Return Temperature RT Input Outside Temperature State Flame Failures Bas Outd T DHW Temperature Fan Speed Flue Temp Error Operation Days Des...

Page 19: ...Week Date Metric C Bar Filter Error Type Language Date Time Unit Type Burn hours since last service Reset Service Reminder Clear Service History Blocking Fran ais Daylight Savings Time Date Order Date...

Page 20: ...st 97 IO Configuration 74 Emergency Setpoint 156 Permit EmergencyMode 1 CH Mode 75 Delay Per Start Next Mod 157 Emergency Setpoint 110 CH Min Setpoint 153 PwrMode2 Hystersis 180 PwrMode2 Min Power 3 C...

Page 21: ...Ext Zones in Group Enabled Active Day s Interval 1 Interval 2 Interval 3 Enabled Period Disabled 00 00 23 50 00 00 23 50 00 00 23 50 Monday Friday Monday Tuesday Sunday Zones CH Disabled Disabled Sate...

Page 22: ...nt On 1 7 Off Group Active Day s 1 8 Interval 1 Interval 2 Interval 3 Period Disabled Holiday Setpoint Begin Date End Date 00 00 23 50 00 00 23 50 00 00 23 50 Monday Friday Monday Tuesday Sunday Sater...

Page 23: ...em On Temp On Date Holiday Setpoint System Test Outdoor Temp Below Off Test State 32 0 F 122 0 F 0 0 C 50 0 C Comfort Fan Speed Eco Ionisation Anti Fr Reduced Begin Date Begin Date End Date End Date 0...

Page 24: ...rature for climatic regulation 86 194 30 90 176 80 F C U Heating M1 20 Design Outdoor Temp Defines the minimum outdoor tem perature to which the maximum set point can be associated for climatic regula...

Page 25: ...10 seconds after closing the gas valve 21 FLAME_BEFORE_IGNIT Flame is detected before ignition 23 CORRUPTED_ERROR_NR Error code RAM byte was corrupt ed to an unknown error code 29 PSM_ERROR Internal...

Page 26: ...ed up in order to fa cilitate de aeration Gas is not released from the water at low temperatures 9 9NOTE An automatic air purge can be performed during the first ignition The parameter that sets the a...

Page 27: ...O NA must be provided with a means of filling the system to be connected to the appliance s return line RI Before filling or draining the system switch the system s master switch to the OFF position a...

Page 28: ...er 9 9NOTE Please contact your qualified local service technician to have your appliance serviced If you do not have a service tech nician please contact your local R distributor and they will provide...

Page 29: ...e that condensate drains are inspected and ensure that condensate is being directed to appropriate condensate management system or drain as required by local codes Check that the area is free from com...

Page 30: ...fter a number of hours defined in the maintenance plan When this maintenance activity is required the following text ap pears on the normal display Maintenance required This text will remain active un...

Page 31: ...under or over pressure operation Get setting and flue gas test Gas conversion NG LPG propane Gas pressure W C mbar Gas static supply pressure W C mbar Selected maximum output MBH KW Selected minimum o...

Page 32: ...er operation of all modes and settings check carried out Leak test carried out on the gas and water sides Venting installed and secured properly per the vent manufacturer instructions Commissioning in...

Page 33: ...ate shall be perma nently mounted to the exterior of the building at a minimum height of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled...

Page 34: ...s of the boiler shall be free from leakage thermal shock and condensate corrosion and shall be free from defects in material and workmanship for TEN 10 YEARS from the date of manufacture which date i...

Page 35: ...nder which the failure happened Information about the hydraulic system flow rate length of the venting system installation scheme and total heating power of the system Identify of the Qualified instal...

Page 36: ...e Blvd Mississauga ON L5N6H6 CANADA Technical Support Hotline 1 800 474 3556 Professional Resources www riello com The manufacturer strives to continuously improve all products appearance dimensions t...

Reviews: