30
START CONDENS 25 IS
8.1 - Multigas table
Description
Methane gas (G20)
Propane (G31)
Lower Wobbe index (at 15°C-1013 mbar)
MJ/m
3
S
45.67
70.69
Net Calorific Value
MJ/m
3
S
34.02
88
Supply nominal pressure
mbar
mm C.A.
20
203.9
37
377.3
Supply minimum pressure
mbar
mm C.A.
10
102.0
-
Start Condens 25 IS
Number of diaphragm holes
N°
1
1
Diaphragm holes diameter
Ø mm
4,8
3.8
Heating maximum gas capacity
Sm
3
/h
kg/h
2.12
-
-
1.55
DHW maximum gas capacity
Sm
3
/h
kg/h
2.64
-
-
1.94
Heating minimum gas capacity
Sm
3
/h
kg/h
0.53
-
-
0.39
DHW minimum gas capacity
Sm
3
/h
kg/h
0.53
-
-
0.39
Number of fan rotations with slow ignition
rpm
4.000
4.000
Maximum number of heating fan rotations
rpm
4.900
4.900
Maximum number of DHW fan rotations
rpm
6.100
6.100
Minimum number of heating fan rotations
rpm
1.400
1.400
Minimum number of DHW fan rotations
rpm
1.400
1.400
8.2 - ErP data table
Parameter
Symbol
Start Condens 25 IS
Unit
Seasonal energy efficiency class for heating
A
Energy efficiency class for water heating
-
Nominal output
Pn
20
kW
Seasonal energy efficiency for heating
η
s
93
%
useful heat output
At nominal heat output and in high temperature mode (*)
P4
19.5
kW
At 30% of nominal heat output and in low temperature mode (**)
P1
6.5
kW
Efficiency
At nominal heat output and in high temperature mode (*)
η
4
88.1
%
At 30% of nominal heat output and in low temperature mode (**)
η
1
98.1
%
Auxiliary electric consumption
With full load
elmax
29.0
W
With partial load
elmin
10.4
W
In standby
PSB
2.4
W
Other parameters
Heat losses in standby
Pstby
40.0
W
Energy consumption of the pilot flame
Pign
-
W
Annual energy consumption
QHE
38
GJ
Sound power level inside
LWA
50
dB
Nitrogen oxide emissions
NOx
19
mg/kWh
production
Load profile declared
-
Daily electricity consumption
Qelec
-
kWh
Annual electricity consumption
AEC
-
kWh
Energy efficiency for water heating
η
wh
-
%
Daily fuel consumption
Qfuel
-
kWh
Annual fuel consumption
AFC
-
GJ
(*) in high temperature mode: 60°C on return and 80°C on delivery.
(**) in low temperature mode: Return temperature 30°C.
NOTE
With reference to Delegated Regulation (EU) No 811/2013, the data represented in the table may be used for the completion of the product
sheet and the labelling of ambient heating appliances, mixed heating appliances, the sets of ambient heating appliances, temperature control
devices and solar devices:
Outdoor probe connected in boiler
Component
Class
Bonus
External probe
II
2%
Control panel
V
3%
outdoor probe + command panel
VI
4%
9
The parts concerning the DHW should only be considered when connected to a storage tank (accessory available on request).