35
INSTALLATION
ENGLISH
STAND ALONE mode
with 2 Thermostats / Chrono-thermostats and 1 FAMILY REC
TR1
M2
M7
M9
M11
M8
M10
M6
M12
ST1
(*)
(*)
M4
JP3
JP2
JP4
JP5
JP1
JP6
ST7
ST8
ST2
ST3
ST4
ST5
CH1
CH2
CH3
ST9
ST6
TR1
TR2
TR3
PT1A
PT1B
PT1C
1 2 3
4 5 6
7 8 9 10
11 12 13 14 15 16 17 18 19 20
21
22
32
33
34
35
36
37
38
39
40
41
1
2
3
1
2
3
1
2
3
1
2
1
2
1 2
1 2
1 2 3
1 2 3 4 5
1
2
3
4
5
1 2
1 2
1 2
1
2
3
4
5
6
1 2 3
M1C
M1B
M1A
23
24
25
26
27
28
29
30
31
SE
TAC
TA/CT
IAT
TA/CT
IBT2
FREC
IBT1
TAC
Connection to ambient thermostat
of boiler (M6 21-22)
SE
External sensor (M12 36-37)
TA/CT IAT
Ambient
thermostat/chrono-thermostat
HIGH temperature system (M1C 30-31)
FREC IBT1
Remote control FAMILY REC for
LOW temperature system 1 (M1A 25-24)
TA/CT IBT2
Ambient
thermostat/chrono-thermostat
LOW temperature system 2 (M1B 27-26)
(*)
The jumpers to the terminals ST1 and JP6 must be set to
the factory default position.
STAND ALONE mode
with 2 REC 08 and 1 FAMILY REC
TR1
M2
M7
M9
M11
M8
M10
M6
M12
ST1
(*)
(*)
M4
JP3
JP2
JP4
JP5
JP1
JP6
ST7
ST8
ST2
ST3
ST4
ST5
CH1
CH2
CH3
ST9
ST6
TR1
TR2
TR3
PT1A
PT1B
PT1C
1 2 3
4 5 6
7 8 9 10
11 12 13 14 15 16 17 18 19 20
21
22
32
33
34
35
36
37
38
39
40
41
1
2
3
1
2
3
1
2
3
1
2
1
2
1 2
1 2
1 2 3
1 2 3 4 5
1
2
3
4
5
1 2
1 2
1 2
1
2
3
4
5
6
1 2 3
M1C
M1B
M1A
23
24
25
26
27
28
29
30
31
SE
TAC
REC 08
IAT
REC 08
IBT2
FREC
IBT1
TAC
Connection to ambient thermostat
of boiler (M6 21-22)
SE
External sensor (M12 36-37)
REC08 IAT
Remote
control
HIGH temperature system (M1C 31-30)
FREC IBT1
Remote control FAMILY REC for
LOW temperature system 1 (M1A 25-24)
REC08 IBT2
Remote control
LOW temperature system 2 (M1B 28-27)
(*)
The jumpers to the terminals ST1 and JP6 must be set
to the factory default position.
9
The Ambient Thermostats and the Chrono-thermostats
must have a dry contact (potential free).
STAND ALONE mode
with 3 REC 08
TR1
M2
M7
M9
M11
M8
M10
M6
M12
ST1
(*)
(*)
M4
JP3
JP2
JP4
JP5
JP1
JP6
ST7
ST8
ST2
ST3
ST4
ST5
CH1
CH2
CH3
ST9
ST6
TR1
TR2
TR3
PT1A
PT1B
PT1C
1 2 3
4 5 6
7 8 9 10
11 12 13 14 15 16 17 18 19 20
21
22
32
33
34
35
36
37
38
39
40
41
1
2
3
1
2
3
1
2
3
1
2
1
2
1 2
1 2
1 2 3
1 2 3 4 5
1
2
3
4
5
1 2
1 2
1 2
1
2
3
4
5
6
1 2 3
M1C
M1B
M1A
23
24
25
26
27
28
29
30
31
SE
TAC
REC
IAT
REC
IBT2
REC
IBT1
TAC
Connection to ambient thermostat
of boiler (M6 21-22)
SE
External sensor (M12 36-37)
REC IAT
Remote control REC 08
HIGH temperature system (M1C 31-30)
REC IBT1
Remote control REC 08 for
LOW temperature system 1 (M1A 25-24)
REC IBT2
Remote control REC 08
LOW temperature system 2 (M1B 28-27)
(*)
The jumpers to the terminals ST1 and JP6 must be set to
the factory default position.
9
The Ambient Thermostats and the Chrono-thermostats
must have a dry contact (potential free).