![Rieber navioven Operating Instructions Manual Download Page 26](http://html.mh-extra.com/html/rieber/navioven/navioven_operating-instructions-manual_1459151026.webp)
Use
26
Rieber GmbH & Co. KG
Humidification function key
In order to use this function you must fill the water tank with drinking water beforehand, up
to a maximum of 1 cm below the top, around 0.5 l.
Make sure there is always drinking water in the tank.
Top up the drinking water
regularly
.
Humidification levels
The air humidification function prevents cooked product from drying out and improves
heat transfer.
4 air humidification levels are available:
0
: Neutral setting, no humidification
Dry: The valve is opened
1 and 2: Controlled humidification
Query humidification level
Press the
Humidification function key
(7).
▌
The set level is displayed.
Set humidification level
Press and hold down the
Humidification function key
.
Adjust the humidification level by turning the
dial
.
Release the
Humidification function key
.
▌
The set value is accepted automatically.
▌
The current chamber temperature is shown in the display again.
▌
When 50°C is reached, the water pump starts with a pre-pumping time of
6 seconds. Water can enter the interior during this process.
Pump residual water out of the appliance, rinse the appliance
See ‘Pump residual water out of the appliance, rinse the appliance’, page 40
Descale the appliance
See ‘Descale the appliance as required, page 45’
START button
Start program
Press
START button
(12).
▌
The selected program starts with the saved settings.
STOP button
Reset functions at any time
Press the
STOP button
(11) and hold for around 5 seconds.
▌
Back to the functions. These can be reset, as described above. The
running program is interrupted.
Press the
START button
(12) to continue the program.
▌
The current chamber temperature is shown in the display again.