IMPORTANT SAFETy INSTRUCTIONS

DANGER:

Carbon Monoxide.

 Using a generator indoors CAN 

KILL YOU IN MINUTES.
Generator exhaust contains high levels of carbon 
monoxide (CO), a poisonous gas you cannot see or 
smell. If you can smell the generator exhaust, you 
are breathing CO. But even if you cannot smell the 
exhaust, you could be breathing CO.

 

Never use a generator inside homes, garages,  

 

crawlspaces,  or  other  partly  enclosed  areas.   

 

Deadly levels of carbon monoxide can build up 

 

in these areas.  Using a fan or opening windows 

 

and doors does NOT supply enough fresh air.

 

ONLY  use  a  generator  outdoors  and  far  away   

 

from  open  windows,  doors,  and  vents.  These 

 

openings can pull in generator exhaust.

Even when you use a generator correctly, CO may 
leak into the home. ALWAYS use a battery-powered 
or battery-backup CO alarm in the home.
If  you  start  to  feel  sick,  dizzy,  or  weak  after  the 
generator  has  been  running,  move  to  fresh  air 
RIGHT AWAY. See a doctor. You could have carbon 
monoxide poisoning.

WARNING:

Read  and  understand  all  instructions.  Failure 
to  follow  all  instructions  listed  below  may  result 
in  electrocution,  fire,  and/or  carbon  monoxide 
poisoning,  which  will  cause  death  or  serious 
injury.

WARNING:

National  Electric  Code  requires  generator  to  be 
grounded  to  an  approved  earth  ground.  Before 
using  the  ground  terminal,  consult  a  qualified 
electrician,  electrical  inspector,  or  local  agency 
having jurisdiction for local codes or ordinances 
that apply to the intended use of the  generator.

SAVE THESE INSTRUCTIONS

This manual contains important instructions for this product 
that should be followed during installation and maintenance 
of the generator.

 

Do not connect to a building’s electrical system unless 
the  generator  and  transfer  switch  have  been  properly 
installed and the electrical output has been verified by a 
qualified electrician.

 

Do not allow children or untrained individuals to use this 
unit.

 

Never start or run the engine inside a closed or partially 
enclosed area. Breathing exhaust fumes will kill you.

 

Always wear eye protection with side shields marked to 
comply  with  ANSI  Z87.1  as  well  as  hearing  protection 
when operating this equipment.

 

Keep all bystanders, children, and pets at least 10 feet 
away.

 

Wear sturdy and dry shoes or boots. Do not operate while 
barefoot.

 

Do not operate generator when you are tired or under the 
influence of drugs, alcohol, or medication.

 

Keep all parts of your body away from any moving parts 
and all hot surfaces of the unit.

 

Do not touch bare wire or receptacles.

 

Do not use generator with electrical cords which are worn, 
frayed, bare, or otherwise damaged.

 

Before storing, allow the engine to cool and drain fuel 
from the unit.

 

Do not operate or store the generator in rain, snow, or 
wet weather.

 

Store  the  generator  in  a  well-ventilated  area  with  the 
fuel  tank  empty.  Fuel  should  not  be  stored  near  the 
 generator.

 

Empty fuel tank, close fuel valve, and restrain the unit 
from moving before transporting in a vehicle.

 

Allow engine to cool for five minutes before refueling.

 

To reduce the risk of fire and burn injury, handle fuel with 
care. It is highly flammable.

 

Do not smoke while handling fuel.

 

Store fuel in a container approved for gasoline.

 

Position the unit on level ground, stop engine, and allow 
to cool before refueling.

 

Loosen fuel cap slowly to release pressure and to keep 
fuel from escaping around the cap.

 

Tighten the fuel cap securely after refueling.

 

Wipe spilled fuel from the unit.

 

Never attempt to burn off spilled fuel under any circum-
stances.

 

Generators vibrate in normal use. During and after the 
use  of  the  generator,  inspect  the  generator  as  well  as 
extension cords and power supply cords connected to 
it  for  damage  resulting  from  vibration.  Have  damaged 
items repaired or replaced as necessary. Do not use plugs 
or cords that show signs of damage such as broken or 
cracked insulation or damaged blades.

 

For power outages, permanently installed stationary gen-
erators are better suited for providing back-up power to 
the home. Even a properly connected portable generator 
can become overloaded. This may result in overheating 
or stressing the generator components, possibly leading 
to generator failure.

Summary of Contents for RD6800 Series

Page 1: ...ation avant d employer ce produit Si tous les avertissements et toutes les consignes de s curit s et instructions du manuel d utilisation ne sont pas bien compris ne pas utiliser ce produit Su generad...

Page 2: ...eferenced in the operator s manual Consulter l encart volets afin d examiner toutes les figures mentionn es dans le manuel d utilisation Consulte esta secci n desplegable para ver todas las figuras a...

Page 3: ...odel RDCA6800 N Ground terminal borne de terre terminal de conexi n a tierra O Oil cap dipstick bouchon jauge d huile tapa de relleno de aceite varilla medidora de aceite P Oil drainage bolt vis de vi...

Page 4: ...vis 1 po tornillo 1 pulg G Frame crossbar barre stabilisatrice du cadre travesa o del bastidor 10 9 2 3 1 4 7 6 5 8 11 6 Fig 4 1 Axle essieu eje 2 Wheel roue rueda 3 Flat washer rondelle plate arande...

Page 5: ...ck bouchon jauge d huile tapa de relleno de aceite varilla medidora de aceite B Oil fill hole orifice de remplissage d huile agujero de llenado de aceite A Fig 13 Fig 14 A Fuel cap bouchon de carburan...

Page 6: ...lvula de combustible B Off arret apagado C On marche encendido D Choke lever levier de volet de d part palanca del anegador E Start position position de d marrage posici n de arranque F Run position...

Page 7: ...de aceite A b C A Fuel line conduite de carburant conducto de combustible B Petcock robinet de carburant llave de purga C Fuel valve robinet de carburant v lvula de combustible D Off arret apagado E...

Page 8: ...perated from this generator must be properly grounded by use of a third wire or be Double Insulated It is recommended to 1 Use electrical devices with 3 prong grounded plugs 2 Use an extension cord wi...

Page 9: ...a Breathing exhaust fumes will kill you Always wear eye protection with side shields marked to comply with ANSI Z87 1 as well as hearing protection when operating this equipment Keep all bystanders ch...

Page 10: ...generator s gas tank to overflow when filling Fill to 1 in below the top neck of the gasoline tank to allow for fuel expansion Do not cover the fuel tank cap when the engine is running Covering the fu...

Page 11: ...sion can cause severe burns or death Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Lifting Hazard To reduce the risk of serious injury avoid attempting to lift...

Page 12: ...las ventanas abiertas S lo util celo AL AIRE LIBRE y lejos de ventanas puertas y respiraderos Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a po...

Page 13: ...ft 125 ft 75 ft 25 3000 6000 150 ft 100 ft 30 3600 7200 125 ft 65 ft 40 4800 9600 90 ft Fuel warning No smoking when filling with gasoline Do not overfill Full level is 1 in below the top of the fuel...

Page 14: ...TEST and RESET buttons To test Depress the TEST button This should cause the Reset button to pop out To restore power depress the RESET button Perform this test monthly to ensure proper operation of t...

Page 15: ...rn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Ag...

Page 16: ...the engine control panel cord The 25 ft control panel cord Model RDEC25 has a 120 240 Volt 20 Amp twist lock plug and a 12 Volt DC engine control connector on each end When using this cord with the re...

Page 17: ...void back injury lift with your legs and not your back WARNING Do not use this product if any parts on the Loose Parts List are already assembled to your product when you unpack it Parts on this list...

Page 18: ...epeat with remaining leg ASSEMBLY installing the wheels See Figure 7 Wheels are provided to assist in moving the generator to the desired location and should be installed on the side opposite the reco...

Page 19: ...sonal injury APPLICATIONS This generator is designed to supply electrical power for operating compatible electrical lighting appliances tools and motor loads BEFORE OPERATING the UNIT Only use OUTSIDE...

Page 20: ...e with the engine off check the lubricant level before each use of the generator operation Removable control panel See Figure 14 The removable control panel can be wall mounted and con nected to the g...

Page 21: ...17 18 Turn the engine off O Disconnect any equipment that is plugged into the generator Turn the fuel valve to the OFF position Allow 30 minutes of cool down time before storing the machine For secur...

Page 22: ...ubricant as it drains Unscrew the oil drainage bolt and remove Allow lubricant to drain completely Reinstall the oil drainage bolt and tighten securely Refill with lubricant following the instructions...

Page 23: ...aining the carburetor Turn the engine off O Turn the fuel valve to the OFF position Position a suitable container under the carburetor drain screw to catch fuel loosen the screw maintenance Allow fuel...

Page 24: ...E MAINTENANCE SCHEDULE NOTE If a separate engine manual is provided for this generator please follow the maintenance schedule provided in the engine manual instead of the maintenance information liste...

Page 25: ...tinues contact your nearest authorized service center AC receptacle does not work Circuit breaker is off Item plugged in is defective Turn ON the AC circuit breaker Reset the GFCI Try a different item...

Page 26: ...or routine maintenance The Customer s Responsibility under this warranty shall be to 1 Operate and maintain the SORE engine as specified in the appropriate Owner s Manual 2 Give notice to an authorize...

Page 27: ...World Technologies Inc disclaim any and all express or implied warranties with respect to the gasoline engine One World Technologies Inc P O Box 321 Highway 8 Pickens SC 219671 RIDGID Generator 3 YEAR...

Page 28: ...manship that cause the failure of a warranted part for a period of two years c The warranty on evaporative emissions related parts will be inter preted as follows 1 Any warranted part that is not sche...

Page 29: ...15 NOTES NOTAS...

Page 30: ...n diam tre d au moins 12 5 mm 1 2 po et tre faite d un mat riau indiqu pour la mise la terre Introduire la tige ou le fourreau une profondeur de 2 4 m 8 pieds Si un fond rocailleux est pr sent moins d...

Page 31: ...des enfants ou personnes n ayant pas re u une formation ad quate utiliser cette unit Ne jamais mettre en marche ou faire tourner le moteur dans une zone ferm e ou partiellement ferm e L inhalation des...

Page 32: ...ur permettre l expansion du carburant Ne pas recouvrir le bouchon du r servoir de carburant lorsque le moteur fonctionne Ne pas respecter cette directive peut causer une panne de moteur ou endommager...

Page 33: ...ifs Un incendie ou une explosion peut entra ner des br lures graves voire la mort Surface chaude Pour viter les risques de blessures ou de dommages viter tout contact avec les surfaces br lantes Dange...

Page 34: ...generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home or garage EVEN IF doors and windows are open Only...

Page 35: ...r l interm diaire d une source de terre approuv e SYMBOLES Caract ristiques lectriques taille du c ble du cordon prolongateur Voir le tableau ci dessous pour v rifier que la taille de c ble des cordon...

Page 36: ...tact avec une mise lectrique la terre telle qu un dispositif de plomberie un sol mouill ou la terre Les prises prot g es par un disjoncteur de fuite la terre ne prot gent pas des court circuits des su...

Page 37: ...e l nergie du g n rateur consiste ajouter des charges en s quence 1 Sans appareil connect au g n rateur mettre le moteur en marche de la fa on d crite dans ce manuel 2 Brancher et mettre en marche la...

Page 38: ...ompression 8 1 1 Syst me de d marrage rappel Syst me d allumage Transistoris Bougie NGK BPR4ES Volume de lubrifiant moteur 1 0 l 1 1 qt Volume de carburant 30 3 l 8 gal Caract ristiques G N RATEUR Ten...

Page 39: ...s assurer que rien n a t bris ou endommag en cours de transport Ne pas jeter les mat riaux d emballage avant d avoir soigneusement examin le produit et v rifi qu il fonctionne correctement Si des pi c...

Page 40: ...emblage INSTALLATION DES ROUES Voir la figure 7 Les roues sont fournies pour aider d placer le g n rateur l endroit d sir et doivent tre install es du c t oppos la lanceur rappel Localiser les pi ces...

Page 41: ...res non recommand s peut entra ner des blessures graves APPLICATIONS C g n rateur est con u pour fournir une alimentation lectrique pour le fonctionnement d clairages d appareils d outils et de charge...

Page 42: ...jusqu ce que le moteur soit compl tement arr t Le panneau de commande amovible comprend deux prises de courant doubles de 120 V prot g es par un disjoncteur de fuite de terre ainsi que des couvercles...

Page 43: ...machinerefroidirpendantenviron30minutesavant de la remiser Pour s curit ins rer le goupille de blocage de la poign e pour obtenir la poign e avant de d placement NOTE Pour maintenir la goupille de ver...

Page 44: ...ur sans le filtre air Ceci entra nerait une usure rapide du moteur VIDANGE DE Le lubrifiant MOTEUR Voir la figure 23 Retirer le bouchon la jauge d huile Placer un r cipient sous la vis de vidange d hu...

Page 45: ...on 25 4 mm 1 po Lorsque le carburant est vidang du r servoir fermer le robinet de carburant et r installer la conduite sur le petit robinet VIDANGE DU CARBURATEUR Mettre le contacteur du moteur sur ar...

Page 46: ...est fourni avec cette g n ratrice veuillez respecter le calendrier d entretien pr sent dans le manuel du moteur au lieu de suivre les instructions d entretien d crites ci dessous Avant chaque utilisa...

Page 47: ...n Vidanger le carburant et le carburateur Remplir d essence fra che La prise c a ne fonctionne pas Disjoncteur d clench L appareil branch est d fectueux Enclencher le disjoncteur c a R initialiser le...

Page 48: ...placement de toute pi ce en raison de l usure normale ou de l entretien r gulier Il sera de la responsabilit du client en vertu de la pr sente garantie 1 d utiliser et d entretenir le moteur SORE tel...

Page 49: ...e du fabricant du moteur et est entretenu par le r seau de centres d entretien autoris du fabricant du moteur Ridgid Inc et One World Technologies Inc en d mentez et toutes les garanties explicites ou...

Page 50: ...us garantie pendant une p riode de deux ans c La garantie sur les pi ces relatives aux missions de vapeurs de carburant doit tre interpr t e de la fa on suivante 1 Toute pi ce de garantie qui n est pa...

Page 51: ...15 NOTES NOTAS...

Page 52: ...ctrico Nacional especifica varias maneras pr cticas para establecer una buena fuente de conexi n a tierra Si se utiliza una barra de acero o de hierro ste debe ser de 15 9 mm 5 8 pulg de di metro y si...

Page 53: ...nes del escape puede ser mortal Al utilizar esta herramienta p ngase protecci n para los ojos con la marca de cumplimiento de las normas ANSI Z87 1 as como protecci n para los o dos Mantenga a todos l...

Page 54: ...i n del combustible Revise el orificio de ventilaci n del interior del tanque de combustible para ver si tiene basura No bloquee el respiradero No fume mientras abastece de gasolina el generador Apagu...

Page 55: ...ivos El fuego o una explosi n pueden causar quemaduras graves e incluso la muerte Superficie caliente Para reducir el riesgo de lesiones corporales o da os materiales evite tocar toda superficie calie...

Page 56: ...D La siguiente informaci n puede encontrarse en el generador Para su propia seguridad le sugerimos estudiar y entender todas la etiquetas antes de poner marcha el generador Si se desprende de la unida...

Page 57: ...de Electricidad exige que el generador est conectado a una tierra aprobada S MBOLoS aspectos el ctricos Calibre del cord n de extensi n Consulte el cuadro mostrado abajo para asegurarse de que el cal...

Page 58: ...miento apague el dispositivo o herramienta de inmediato para evitar da ar el equipo Siempre verifique los requisitos de la herramienta o aparato con la salida nominal del generador Capacidad del motor...

Page 59: ...gar cargas el ctricas al generador NO debe haber equipo alguno conectado a los tomacorrientes del generador antes de poner en marcha el motor respectivo La manera correcta y segura de administrar la p...

Page 60: ...giro de 240 V y 20 A y un conector de control del motor de corr cont de 12 V en cada extremo Al usar este cord n con el panel de control desmontable se pueden energizar los dispositivos adecuados a t...

Page 61: ...ma inadecuada podr a causar lesiones personales graves Inspeccione cuidadosamente la producto para asegurarse que no haya sufrido ninguna rotura o da o durante el transporte No deseche el material de...

Page 62: ...tela para asegurarla Repita lo mismo con la pata restante instalaci n de las ruedas Vea la figura 7 Las ruedas se proporcionan para ayudar a trasladar el gen erador hasta la ubicaci n deseada y deben...

Page 63: ...dise ado para suministrar alimentaci n el ctrica para el funcionamiento de iluminaci n el ctrica compatible electrodom sticos herramientas y cargas de motor ANTES DE ACCIONAR LA UNIDAD S lo util celo...

Page 64: ...ura 14 El panel de control desmontable puede montarse en la pared y conectarse al generador con el cord n de panel de control de 7 62 m 25 pies Modelo n m RDEC25 suministrado con el producto El genera...

Page 65: ...l pasador de seguro del mango para asegurar el mango antes de traslado NOTA Para ayudar a que el pasador de bloqueo del mango se mantenga firme en el orificio empuje el rea acoplada del acollador haci...

Page 66: ...motor cambio del lubricante del motor Vea la figura 23 Retire la tapa de relleno de aceite varilla medidora de aceite Coloque un recipiente bajo el perno de drenaje de aceite para recoger el lubrican...

Page 67: ...grifo de descompresi n de combustible 25 4 mm 1 pulg aproximadamente Unavezquesehayadrenadotodoelcombustibledeltanque cierre la v lvula y vuelva a instalar el conducto en la llave de purga drenaje del...

Page 68: ...dad PROGRAMA DE MANTENIMIENTO NOTA Si recibe un manual del motor para este generador en particular respete el cronograma de mantenimiento que se indique en el manual del motor y no la informaci n de m...

Page 69: ...tezca de gasolina fresca la unidad Si el problema contin a comun quese con un centro de servicio autorizado No funciona el recept culo de corriente alterna El disyuntor est en apagado off Est defectuo...

Page 70: ...nte tendr la responsabilidad de 1 operar y mantener los motores SORE seg n se especifica en el manual del propietario adecuado 2 notificar a un centro de reparaci n autorizado de motores SORE de Yamah...

Page 71: ...fabricante del motor Ridgid Inc y One World Technologies Inc niega cualquier y todo expresado o las garant as impl citas con respecto al motor de gasolina RIDGID GENERADOR GARANT A DE lIMITADA DE 3 A...

Page 72: ...antizada por un tiempo de dos a os c La garant a en las piezas relacionadas con las emisiones evaporativas ser interpretada de la siguiente manera 1 Cualquier pieza garantizada que no est en el calend...

Page 73: ...15 NOTES NOTAS...

Page 74: ...ur une plaquette fix e au bo tier du moteur Noter le num ro de s rie dans l espace ci dessous Lors de toute commande de pi ces d tach es fournir les informations suivantes No de mod le No de s rie Inf...

Reviews: