2-55
Confidential
• Install the latest main firmware.
Error code E500
An error occurred during access to the DRAM in the main PCB ASSY.
Error code E600
Write error in the EEPROM of the main PCB ASSY
Error code E701
System error in the flash ROM
Error code E702
Read error in the flash ROM
Error code F900
The spec code was not entered correctly.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
The power was turned OFF while
function code 74 was running.
Reenter the spec code. (Refer to
Configure for country/region and model
(Function code 74)” in Chapter 5
2
Main PCB failure
Replace the main PCB ASSY.
Memo:
• Simultaneously pressing the [*] and the [#] clears the error display under error code F900
display, and then the maintenance mode can be selected again.
Summary of Contents for SP 230SFNw
Page 29: ...2 8 Confidential 2 2 2 Scanner part Fig 2 4 Document feed path...
Page 120: ...3 2 Confidential 2 PACKING Fig 3 1 Option carton Carton Polystyrene pad ASSY Spacer carton...
Page 226: ...5 21 Confidential Print adjustment test pattern Fig 5 5...
Page 234: ...5 29 Confidential Print pattern Fig 5 9 W 100 K 1 K 100 Total Lattice K 5...