2-51
Confidential
Error code A700
Color parameter in the ROM does not match the CIS.
Error code A900
A scanning error occurred while processing the scanned image.
Error code AD00
Image processing cannot be completed correctly because the number of pixels required for
image processing is insufficient in the scanned data.
Step
Cause
Remedy
1
Incorrect correction data for the
CIS unit
Execute “Set CIS scan area
”.
2
Damaged the CIS flat cable
Replace the CIS flat cable.
3
CIS unit failure
Replace the CIS unit.
4
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Incorrect correction data for the
CIS unit
Execute “Set CIS scan area
”.
2
Connection failure of the CIS flat
cable
Reconnect the CIS flat cable.
3
CIS unit failure
Replace the CIS unit.
4
White tape failure
Replace the document scanner unit.
5
Main PCB failure
Replace the main PCB ASSY.