3-54
Confidential
8.18 HVPS flat cable / High-voltage power supply PCB ASSY
(1) Disconnect the HVPS flat cable from the High-voltage power supply PCB ASSY. Disconnect
the HVPS flat cable from the Main PCB ASSY, and release it from the securing fixtures.
(2) Disconnect the Fan harness from the High-voltage power supply PCB ASSY.
(3) Remove the Screw cup M3x8 (black) screw. Release each Hook and pull out the right side
of the High-voltage power supply PCB ASSY in the direction of the arrow A to remove it
from the Pins. And then pull out the High-voltage power supply PCB ASSY in the direction
of the arrow B to remove it from the Rib.
Fig. 3-45
Harness routing: Refer to
,
.
Note:
• After disconnecting flat cables, check that each cable is not damaged at its end or
short-circuited.
• When connecting flat cables, do not insert them at an angle. After insertion, check
that the cables are not at an angle.
Assembling Note:
• After attaching the High-voltage power supply PCB ASSY, push the Electrode springs
from inside of the machine to check that nothing is caught. (Refer to
Screw cup M3x8 (black)
Hook
Fan harness
HVPS flat cable
Main PCB ASSY
High-voltage power supply PCB ASSY
Hook
HVPS flat cable
Rib
Pin
Pins
A
B
<Back side>