4. Do not put the machine in areas with sudden temperature changes. This includes:
• Areas directly exposed to cool air from air conditioning
• Areas directly exposed to heat from a heating system.
5. Do not put the machine in areas exposed to corrosive gas.
6. Do not install the machine at locations over 2,000 m (6,562 ft.) above sea level.
7. Put the machine on a strong, level base. (Tilting towards any side must be no more than 3 mm.)
8. Do not put the machine in areas with strong vibrations.
Power Requirement
Power Source: 220 to 240V 50/60 Hz 4A or less
Check the machine installation and confirm the following important points:
• Power plug fits tightly in the outlet.
• Power plug is clean and free of dust.
• The machine power plug is not connected to a shared source.
• The machine should be properly grounded.
• The power cord should be free and not wrapped around the leg of a chair or table, or bundled.
Machine Level
Make sure that the machine is located on a flat surface.
Front to back
Within 5 mm (0.2") of level
Right to left
Within 5 mm (0.2") of level
Space Requirements
The machine should be used in a location that meets these minimum space requirements.
2. Installation
38
Summary of Contents for M178-21
Page 2: ......
Page 24: ...22 ...
Page 71: ...6 Disconnect the thermistor harness 1 7 Disconnect the exit sensor 1 Basic Procedures 69 ...
Page 90: ...Friction Pad 1 Remove 3 screws 3 2 Release 2 tabs 2 4 Replacement and Adjustments 88 ...
Page 103: ...Solenoid 101 ...
Page 105: ...2 Remove the breaker switch screw A 1 3 Disconnect and remove the switch B 2 Switches 103 ...
Page 108: ...4 Replacement and Adjustments 106 ...
Page 190: ...5 System Maintenance Reference 188 ...
Page 221: ...MEMO 219 ...
Page 222: ...MEMO 220 EN ...
Page 224: ......
Page 226: ...2 ...
Page 250: ...MEMO 26 ...
Page 251: ...MEMO 27 ...
Page 252: ...MEMO 28 EN ...