SC547
r2
D
Zerocross Error
Power supply frequency is unstable. HVP or PSU failure.
• To reset the SC code, turn the power On and Off.
• Use more stable power supply.
• Replace the HVP or PSU.
SC557
-
C
Zerocross Frequency Over
Power supply frequency is unstable.
No error message will be issued on this SC. A log of this SC will be
logged in the SOM service mode SC
SC559
c3
A
Fusing Unit Third Jam Error (Fatal Error)
The exit sensor failed to detect the leading edge of the paper within the
prescribed time and triggered a jam alert.
• After this error has occurred three times, the machine will shut down
automatically and cannot be re-started until the machine has been
serviced by a service technician.
• Check the paper transport path for any physical obstructions (paper
scraps, etc.)
• Make sure the fusing unit has been installed correctly
• After servicing the machine to solve the problem, the service
technician must execute a "Fuser SC Reset". Otherwise, the machine
will continue to issue this SC code and cannot be operated. (
page 191)
SC587
C0
A
Motor Thermistor Error
After starting up, inside of the machine temperature would be checked
every 100ms, then the machine is detected -30°C for 4 sec. or 105°C for
a sec.
• Check the connection or replace the thermistor
• Replace the I/F harness
• Replace main board
6. Troubleshooting
198
Summary of Contents for M178-21
Page 2: ......
Page 24: ...22 ...
Page 71: ...6 Disconnect the thermistor harness 1 7 Disconnect the exit sensor 1 Basic Procedures 69 ...
Page 90: ...Friction Pad 1 Remove 3 screws 3 2 Release 2 tabs 2 4 Replacement and Adjustments 88 ...
Page 103: ...Solenoid 101 ...
Page 105: ...2 Remove the breaker switch screw A 1 3 Disconnect and remove the switch B 2 Switches 103 ...
Page 108: ...4 Replacement and Adjustments 106 ...
Page 190: ...5 System Maintenance Reference 188 ...
Page 221: ...MEMO 219 ...
Page 222: ...MEMO 220 EN ...
Page 224: ......
Page 226: ...2 ...
Page 250: ...MEMO 26 ...
Page 251: ...MEMO 27 ...
Page 252: ...MEMO 28 EN ...