MASTER FEED SECTION
1 July, 1998
6-42
4. Close the duct entrance plate [A] by hand and secure the link [B] with tape.
NOTE: This procedure must be done to obtain fine adjustment.
5. Slide in the master making
unit and make sure that the
drum is installed.
6. Turn on the main switch,
then access SP6-20-6
(Sensor Voltage and
Threshold Adjustment for
Master Edge Sensor).
7. Remove the rear cover and
access the I/O board. Turn
VR307 [C] clockwise until
LED303 [D] lights.
8. The sensor input voltage is
displayed on the operation
panel. Check that it is
between 0.85 and 0.95
volts. If it is not, repeat step
7.
9. Leave the SP mode.
C229R533.WMF
C229R104.WMF
[C]
[D]
[A]
[B]