Switch 07 - Various
Digit
Purpose
0 to 1
Do not change these settings.
2
Parallel Memory Transmission
0: Off
1: On*
3
Auto Reduce
0: Off
1: On*
4 to 7
Do not change these settings.
Switch 08 - Various
Digit
Purpose
0, 1
Multi-sort reception
Digit 1 Digit0 Setting
X
0 Off*
0
1 Messages from senders whose RTI/CSIs
are programmed are multi-copied.
1
1 Messages from senders whose RTI/CSIs
are not programmed are multi-copied.
2, 3
Authorized Reception
Digit 3 Digit 2 Setting
X 0
Off *
0 1
Receive messages only from
senders whose RTI/CSIs are
programmed.
1 1
Receive messages only from
senders whose RTI/CSIs are not
programmed.
4, 5
Specified Cassette Selection (Optional Lower Cassette Required)
Digit 5 Digit 4 Setting
X 0
Off*
0 1
Print Special Terminal’s messages
using the main cassette, but don’t
print any others with cassette.
1 1
Don’t print Special Terminal’s
messages using the main cassette.
6, 7
Forwarding
Digit 7 Digit 6 Setting
X 0
Off*
0 1
Forward messages only from
senders whose RTI/CSIs are
programmed
1 1
Forward messages only from
senders whose RTI/CSIs are not
programmed.
ON/OFF SWITCHES AND USER PARAMETERS
TECHNICAL REFERENCE
188