Chapter 3 1 Exterior
3.0±1.0 mm
Should be parallel
Nut
Screw
● Ejecting side
The distance between the scanner cover
and ADF should be 3.0±1.0 mm.
b. Feeding side
The ADF and scanner should be parallel
each other.
● ADF side (feeding side)
The arrowed part should contact the
scanner cover.
● Adjusting the height of the ADF
IMPORTANT
Loosen the nuts on the left and right hinges,
and then use a hexagonal wrench to adjust
the height by turning the screws.
As the height of the ADF is adjusted
before shipping, do not adjust it except
when required.