8.2
TWO-SIDED ORIGINAL
The Original Misfeed indicator lights if the registration sensor is not actuated
within 540 milliseconds after the belt drive motor starts turning (ON check), or
if the registration sensor does not turn off within 780 milliseconds after the
registration sensor turns on (OFF check). If the feed-out sensor is not
actuated within 780 milliseconds after the registration sensor turns off, the
Original Misfeed indicator lights (ON check). The Original Misfeed indicator
also lights if the feed-out sensor does not turn off within 780 milliseconds
after the feed-out sensor turns on (OFF check).
The feed-out ON/OFF check is same as for one-sided originals.
Registration
OFF check (780 ms)
ON check (780 ms)
Feed-out
Belt Drive Motor
Feed-out Motor
ON check (540 ms)
OFF check (780 ms)
Sensor
Sensor
Forward
Reverse
ORIGINAL MISFEED SENSING
12 February 1992
18