5. If the paper has not stopped against the left scale [A], remove the left
scale (2 shoulder screws).
6. Set a sheet of A4 / 8
1/2"
x 11" paper [B] sideways on the exposure glass
edge as shown.
NOTE: This sheet of paper prevents the original from jamming at the
edge of the exposure glass when it is fed in without the left scale.
7. Set a sheet of A3 / 11" x 17" paper on the DF then press SW101.
8. Just after the paper is fed in, gently pull off the sheet set in step 6.
9. When the paper (set in step 7) stops on the exposure glass after the
inversion, open the DF slowly so that the paper does not move from the
stop position.
[B]
[A]
ARDF
12 February 1992
REPLACEMENT AND ADJUSTMENT
47