GTR211 Installation Manual:
Rev 1
19
Step 10 - Testing the Limit Travel Stops:
Testing the closed position
• Ensure motor is plugged in as per step 9 and the gate is in the open position.
•
Press remote (remotes included in kit are factory paired to the motor). The gate will begin
to close.
• The limit travel stop will hit the spring limit switch and the gate will stop.
• When the gate stops, measure the distance remaining between the gate and the desired
closed position.
• You have now determined the closed position of the gate when the travel limit stop hits the
spring limit switch.
•
Adjust the limit travel stop from the measurement you have taken to get your final
gate closed position. The ideal closed final position for the gate frame is 10-15mm
from closed gate end catch (GTR019).
Testing the open position
• Press remote. The gate will begin to open.
• The limit travel stop will hit the spring limit switch and the gate will stop.
• When the gate stops, measure the distance remaining between the gate and the desired
open position.
• You have now determined the open position of the gate when the travel limit stop hits the
spring limit switch.
•
Adjust the limit travel stops from the measurement you have taken to get your final
gate open position. The ideal open final position for the gate frame is 10-15mm from
the gate stopper (GTR017).
To Reset:
When setting new limit travel stop positions please ensure that you turn the power off and
then on again. Turning the power off will reset the limit travel stop memory, allowing for new
limit travel stop positions to be recognised by the motor.
Fig 24