Dip Switch Adjustment
All changes to these settings must be completed by a licensed electrician
Number
Description
Soft Start/Close Function
OFF - enabled
ON - disabled
Default position is OFF (recommended)
Limit Switch Setting (disable or enable the spring limit switch)
OFF – Normal Open
ON – Normal Close
Default position is ON,
this should not be changed.
Remote Control Close Function
3 OFF 4 OFF: Factory default setting:
The gate is operated by remote control operation only and will not close
automatically. The gate will remain open until closed again with a remote.
Optional Automatic Close Function:
Richmond strongly recommends that you install infrared photocells if
using the motor in auto close mode.
3 OFF 4 ON: automatic close delay time is 12s.
3 ON 4 OFF: automatic close delay time is 24s.
3 ON 4 ON: automatic close delay time is 36s.
3 ON 4 OFF: Hard wire keypad. Automatic close function.
Stall Force Mode (When in default position, detects obstacles,
stops gate, and reverses. To adjust, refer to VR1: Stall Force Mode)
Default position is OFF (enabled)
this should not be changed.
If the switch is set to ON, stall force mode will be disabled