GTR061 Installation Manual:
Rev 3
4
It is recommended that you allow a minimum 500mm bottom rail extension
from your inside gate post opening. This will enable you to have enough
room to secure your gear rack and placement for the motor.
Gate Opening Default Setting Information:
The gate motor will open the gate to the right-hand side as its default setting (refer to fig 1).
MIN 500mm
MIN 500mm
Default operation:
Motor mounted on
the right-hand side
Left-Hand Opening:
Motor mounted on the
left-hand side
Fig 1
Before Installing:
Test the motor by plugging it into a power source and pressing the remote. You will see the motor
cog turn. When it stops (after approx 1 minute), press the remote again to see it turn in the opposite direction. This will
give you an understanding of the way in which the motor will move the gate.
Press the first/top button
on the remote.
Note: Ensure that the motor is unplugged before proceeding with installation. Please keep fingers away from the motor cog whilst it is turning.
Any works done to the motor must be completed whilst the power is off and the motor is unplugged
The motor cog will turn counter-clockwise,
moving the gate frame.
The gate will then move in the set
direction. Default: right-hand open.
If your gate needs to open from the other direction (to the left, refer to fig 2) your motor needs to be mounted on the left-hand side as
shown below, you will need to switch DIP SWITCH 5 from OFF to ON (refer to page 22).
Fig 2
It is recommended that you allow a minimum 500mm bottom rail extension
from your inside gate post opening. This will enable you to have enough
room to secure your gear rack and placement for the motor.