GTR061 Installation Manual:
Rev 3
18
Step 9 - Testing the Limit Travel Stops:
Testing the closed position
• Ensure motor is plugged in as per step 8 and the gate is in
the open position.
• Press remote (remotes included in kit are factory paired to the
motor). The gate will begin to close.
• The limit travel stop will hit the spring limit switch and the gate
will stop.
• When the gate stops, measure the distance remaining
between the gate and the desired closed position.
• You have now determined the closed position of the gate
when the travel limit stop hits the spring limit switch.
• Adjust the limit travel stop from the measurement you have taken to
get your final gate closed position. The ideal closed final position for
the gate frame is 10-15mm from closed gate end catch (GTR019).
Testing the open position
• Press remote. The gate will begin to open.
• The limit travel stop will hit the spring limit switch and the
gate will stop.
• When the gate stops, measure the distance remaining
between the gate and the desired open position.
• You have now determined the open position of the gate when
the travel limit stop hits the spring limit switch.
• Adjust the limit travel stops from the measurement you have taken
to get your final gate open position. The ideal open final position for
the gate frame is 10-15mm from the gate stopper (GTR017).
To Reset:
When setting new limit travel stop positions please ensure that you turn the power
off and then on again. Turning the power off will reset the limit travel stop memory, allowing
for new limit travel stop positions to be recognised by the motor.
Fig 24
Warning:
Please allow space to ensure the
gate does not impact against the
gate catch or the end stop. See fig 24