Indicator Installation and Configuration
9
4.3.1
Configuration Mode
To get into the configuration mode, turn the scale off and remove the configuration jumper as shown in
Figure 4-3. Turn the scale on. While
Start
is displayed, press and hold the
Kg-Lb
key until
IDENT
appears on the
display.
To change from one parameter to the next, press the
REWEIGH
key once.
To change the value of the parameter, use the
Kg-Lb
key.
From the
SAVE
phase: to save the configuration data, press the
REWEIGH
key.
DONE
appears for one or two
seconds followed by
Start
and the display enter into weighing mode and is ready to start the weighing process. To
exit with saving changes, press the
Lb/Kg
key.
Varous parameters can be set up while in configuration mode
Table 4-1. Programming Mode Menu Structure
Numeric Data Entry
Use the
Kg-Lb
key to change the numeric data entry while setting up the various configuration parameters and
while in calibration mode.
Use the following steps:
1. Press and hold the
Kg-Lb
key, the rightmost digit on the display will begin to increment.
2. Release the
Kg-Lb
key to stop the increments.
3. A double click on the
Kg-Lb
key will cause the right hand digit to move one place to the left.
Repeat steps 1-3 until the desired number is reached.
Power Off
Power On-Off
START
Kg-Lb Key
0.000
Software Version
Round xx
Full xxx
A TOLXX
Drange
At
Press and
hold
A LEN X
MESS
A TImE XX
BAUD XX
OP1=X
SAVE
T-OFFX
DONE
OP2=X
OP4=X
OP3=X
OP5=X
OP7=X
OP6=X
OP8=X
Press and
hold the
Kg-Lb key
to advance
to option
2 through
option 8.
= DEF =
Software ID
SET=X
OP9=X
OP10=X