10
Summit SB-1000 Bariatric Wheelchair Scale Installation Manual
The following table lists the various display messages and sequence when setting up the scale.
NOTE:
<-> means that you can toggle between two values.
Step
Function
Display
Available Parameters
1
With the scale turned
off, remove the
confiiguration jumper
as shown in
Figure 4-3.
Allows the scale to enter into either
configuration or calibration mode.
2
With the scale turned
off, simultaneously
press the
On-Off/Zero
and
Kg-Lb
key.
Enters into
programming mode
StArt
Scale automatically advances to Step
3.
3
Indentifies the
software ID
IdEnt<->
11007
Press the
REWEIGH
key to advance
to the next step.
4
Identifies software
version
Id<->11305
Press the
REWEIGH
key to advance
to the next step.
5
Allows selection of
decimal point setting
dOt<->000.0
Default =
0.0
To change the position of the decimal
point, press the
Kg-Lb
key to toggle
through the various options. To
advance to the next step, press the
REWEIGH
key.
6
This indicates the
maximum allowed
weight. Any weight
above this value will
cause
StOP
to appear
on the display while in
the weighing mode.
FULL<->XX.XXX
Default=
600 Lb
Note:
This value is
dependent on the model you
have. Refer to the serial
number label on your scale
and set appropriately.
Use the numeric data entry (See
“Numeric Data Entry” on page 9.) to
change the value. To advance to the
next step, press the
REWEIGH
key.
7
Display divisions
rOUnd<->XXXX
Default =
0.2 Lb
To change the display divisions, press
the
Kg-Lb
key to toggle through the
various options.
0.2, 0.5, 1.0, 2.0, 5.0, 10.0, 20.0.
To advance to the next step, press the
REWEIGH
key.
8
Double ranges limit
drAnGe <->
0
This parameter is preset from the
factory. To advance to the next step,
press the
REWEIGH
key.
9
Weight algorithm initial
tolerance
A tOL <->
10
This parameter is preset from the
factory. To advance to the next step,
press the
REWEIGH
key.
10
Weight algorithm initial
exponent
A LEn <->
8
This parameter is preset from the
factory. To advance to the next step,
press the
REWEIGH
key.
11
Weight algorithm
maximal exponent
A t INE <->
10
This parameter is preset from the
factory. To advance to the next step,
press the
REWEIGH
key.
Table 4-2. Configuration Mode Menu