820i Programmable HMI Indicator/Controller
88
Visit our website
Command
Description
Values
DON.
b
#
s
Set digital output on (active) at bit
b
, slot
s.
—
DOFF.
b
#
s
Set digital output off (inactive) at bit
b
, slot
s.
—
DIO
.b
#
s
Digital input function
OFF, INPUT, OUTPUT, PROGIN, ZERO, NT/GRS, TARE,
UNITS, PRINT, ACCUM, SETPNT, TIMDATE, ESC, CLEAR,
DSPTAR, IDKEY, KEY0–KEY9, KEYDP, ENTER, NAVUP,
NAVDN, NAVLFT, NAVRGT, KBDLOC, HOLD, BATRUN,
BATSTRT, BATPAUS, BATRESET, BATSTOP, CLRCN,
GROSS, NET, PRIM, SEC, CLRTAR, CLRACC, TRIGGER
DIO.TRIG_SLOT
.b
#
s
Trigger output slot
NONE, SLOT3
DIO.TRIG_PARAM
.b
#
s
Trigger output parameter
value
Digital inputs and outputs are specified by bit number (
b
) and slot number (
s
)
Table 9-8. DIG I/O Serial Commands
Command
Description
Values
ALG.ALIAS#
s
Analog output alias
name
ALG.SOURCE#
s
Analog output source
PROG, SCALE
n
ALG.MODE#
s
Mode
GROSS, NET
ALG.OFFSET#
s
Zero offset
0%, 20%
ALG.ERRACT#
s
Error action
FULLSC, HOLD, ZEROSC
ALG.MIN#
s
Minimum value tracked
0–9999999
ALG.MAX#
s
Maximum value tracked
0–9999999
ALG.ZERO#
s
Zero calibration
0–65535
ALG.SPAN#
s
Span calibration
0–65535
For commands ending with “#
s
”,
s
is the slot number.
Table 9-9. ALGOUT Serial Commands (Valid Only If Analog Output Card Is Installed)
Command
Description
Values
XP#
s
Extract probe temperature
—
XPP#
s
Extract probe primary temperature
XPS#
s
Extract probe secondary temperature
XPT#
s
Extract probe tertiary temperature
XI#
s
Extract 0–20 mA value
XV#
s
Extract 0–10 V value
For commands ending with “#
s
”,
s
is the slot number.
Table 9-10. Analog Input Serial Commands (Valid Only If Analog Input Card Is Installed)
Summary of Contents for 820i