820i Programmable HMI Indicator/Controller
34
Visit our website
PORTTYPE
232
485
Specifies whether Port 4 is used for RS-232 or RS-485 communications. If 485 is selected, additional prompts
are shown to specify half- or full-duplex operation and RS-485 address.
NOTE: RS-485 communications can be specified for Ports 4 and 7.
DUPLEX
HALF
FULL
Specifies whether the RS-485 communications is half- or full-duplex.
ADDRESS
0
0–255
Specifies the decimal indicator address for RS-485 connections. RS-232 communications is disabled if an
address other than zero is specified for this parameter. RS-485 addresses must be in the range 01–255.
STREAM
OFF
LFT
INDUST
4KEYS
KEYPAD
DISPLAY
Specifies what data, if any, is streamed from the port.
4KEYS and KEYPAD stream keypad events to a receiving indicator. KEYPAD transmits all keypad events;
4KEYS transmits keypresses of the
ZERO
,
GROSS/NET
,
TARE
, and
UNITS
keys only.
DISPLAY streams the complete display image to the receiving indicator in local/remote indicator configurations.
for more information.
NOTE: Streaming is not supported for RS-485 connections.
SOURCE
source_scale
If STREAM is set to a value other than OFF, SOURCE specifies the source scale for data streamed from the port.
SFMT
format
Specifies the stream format used for the streamed data (SCALE or IND SC scale types). The default format is
the Consolidated Controls format (see
). See
for information
about custom stream formatting.
TOKENS
PRIMAR
SECNDR
TERTIA
GROSS
INVALID
MOTION
ZERO
NET
OK
RANGE
TARE
If STREAM is set to OFF, the TOKENS parameter can be used to replace tokens used in the data stream from
the indicator front panel. See
for more information about custom stream formatting.
TESTCOM
—
iQUBE
communications tests.
Level 4 Submenus
iQUBE
only
VALIDAT
—
Use
Upload
softkey to retrieve serial numbers of attached
iQUBE
units.
SERIAL Menu
Parameter
Choices
Description
Table 3-6. Serial Menu Parameters (Continued)