minutes.
You can enable or disable the pause time using DIP3 (ON enabled).
S
AFETY EDGE IN OPENING (11-12)
If the safety edge intervenes during the opening of the gate, it
commands the reversal of the movement. This reversal will continue
even if the safety edge remains pressed. During closing the safety edge
is not active.
When the safety edge is not in used, the contacts 11-
12 must be bridged.
NB:
from modification SW.07 on cards KS and KS Super,
operation of fence is as follows:
- during opening stroke, if resistance is encountered, motion is
reversed to close;
- during closure stroke, if resistance is encountered; motion is
reversed to opening
- in case resistance load persists, a further inversion is initiated
after 2 seconds, followed by a third short inversion and thus
signalling an alarm for fence failure or jamming (contact NO).
- in case the fence remains blocked (contact NO), no further
motion is allowed.
P
HOTOCELL 2 (9-12)
If it detects an object during the opening cycle, it then operates the
closing of the gate at the end of the interposition. If it detects one during
the closing cycle, it then operates the opening at the end of the
interposition.
This function is particularly helpful when you want the gate to close
immediately after you passed it.
If it is not used, the contacts 9-12
must be bridged.
C
OURTESY LIGHT (7-8)
It is possible to supply 24Vdc power to the coil of a relay, so as to feed
one lamp or more for a minimum period of 1 second and for a maximum
period of 4 minutes (controlled by the TR trimmer fitted on the
EXPANDER card). The relay is activated at every opening or closing.
When the closing Is finished, the traffic light turned off.
T
RAFFIC LIGHT CONTROL
When the gate is completely closed, both the traffic lights are turned
OFF. During the opening the red light (3-4) turns ON. When the gate si
completly opened the green light (5-6) turns ON, and the red light turns
OFF.
The green light remains turned on until the automatic closing starts. When
the gate is closing, the green light turns off and the red light turns ON.
C
ARTE
EXPANDER PLEX
Code ACG5472
APPLICABLE ONLY TO CARDS KS AND KS SUPER WITH
SOFTWARE REV 07 OR LATER
The EXPANDER PLEX card
allows the control of up to 4 photocells
couples
(one connected to KS card and three connected to the
EXPANDER PLEX card).
Control includes a Self Test of the 4 photocells couples and of the fence,
performed on completion of every opening stroke of the gate.
After every opening the gate closure is therefore allowed only upon
successful completion of the 4 photocells couples Self Test.
MAIN FUNCTIONS
----> MONITORING OF 4 PHOTOCELLS COUPLES
----> PEDESTRIAN OPENING
----> AUTOMATIC PEDESTRIAN CLOSING
----> MANAGEMENT OF THE SAFETY EDGE IN OPENING
----> MANAGEMENT OF THE IMMEDIATE CLOSING BY THE
PHOTOCELL2 INPUT
----> MANAGEMENT OF THE COURTESY LIGHT
----> MANAGEMENT OF THE TRAFFIC LIGHT CONTROL
HEATER
CARD
Cod. ACQ9092 230V - Cod. ACQ9093 120V
This device controls the heating of the operating device when this is
installed in places with very low temperatures.
R
ADIO TRANSMITTER MOON
C
ODE LEARNIG SYSTEM RADIORECEIVERS
RX91/A
quarzata and coupling
code ACG5005
RX91/A
quarzata and terminal board
code ACG5004
RX433/A
super eterodyne and coupling
code ACG5055
RX433/A
super eterodyne and terminal board
code ACG5056
RX433/A 2CH super eterodyne, 2 channel and coupling code ACG5051
RX433/A 2CH super eterodyne, 2 channel and terminal board
follows from page 33
ACG6081 - MOON 433
ACG7025 - MOON 91
ACG6082 - MOON 433
ACG7026 - MOON 91
Summary of Contents for K400 230V
Page 8: ...I I COLLEGAMENTI ELETTRICI centralina KS cod BC07050...
Page 18: ...F F BRANCHEMENTS LECTRIQUES coffret electronique KS cod BC07050...
Page 29: ...G G B B ELECTRIC CONNECTIONS electric board KS code BC07050...
Page 40: ...D D ELEKTROANSCHL SSE elektronische steuerung KS code BC07050...
Page 51: ...E E S S CONEXIONES EL CTRICAS panel electronico KS c d BC07052...