EDGE 2 INPUT (gray wire COM, yellow wire EDGE 2)
dedicated to the safety
strip device. Input enabled only with JP2 on SX.
Attention:
any wire jumper present on the SAFTETY STRIPS terminals of RIB
control panels must be removed.
EDGE 1 INPUT (gray wire COM, yellow wire EDGE 1)
dedicated to the strip
safety device.
Attention:
any wire jumper present on the COM-EDGE terminals of control
panels must be removed.
PHOTOCELL INPUT (gray wire COM, black wire PHOT)
dedicated to
the photocell safety devices.
Attention:
any wire jumper present on the COM-PHOT terminals of control
panels must be removed.
CONTROL BUTTON (gray wire COM, white wire N.O. BUTTON)
Disconnect every wired command from the control panel and connect it to this
white wire of MASTER Wi-Fi OS.
EDGE 2
green wire
COM
gray wire
EDGE 1
yellow wire
PHOT.N.C.
black wire
CONTROL BUTTON
white wire
A/D+ TEST
brown wire
*
**
12/24V ac/dc
2+ 1-
Power feed
12/24V ac/dc
120/230V ac
12/24V ac/dc
4 3
Total opening
control contact
COM-OPEN/K
4 3 2 1
COM
K.BUTTON
12/24V ac/dc
+
-
The Wi-Fi system is operating normally if he
handles all the wired controls (through its
white wire).
In case of using radio receivers and wired
controls (and therefore external to the Wi-Fi
system), for a correct functioning of the
system, these commands must be connected
through the white wire of the MASTER Wi-Fi.
+
-
ATTENTION: The use of the product inside of metal containers can cause a system-malfunction. It is therefore recommended in these cases
to add the aerial code ACG5451 to apply to the metal casing for a perfect reception/transmission of the signals.
ATTENTION: ACTIVATE ON CONTROL PANELS THE PRE-FLASHING FUNCTION (IF AVAILABLE).
It is strongly advisable to avoid using an automatic closing time delay, not longer than 1 minute.
Verify the presence of protection fuse in series on secondary of the control panel.
In case it is not available, please connect a T 200 mA delayed fuse in series
on the MASTER power supply.
- Turn off power to the automation control panel.
NOTE:
The opening of the gate occurs 2 seconds after receiving a push button command. That is done to allow the MASTER Wi-Fi OS card to verify the presence
and correct functioning of the memorized safety devices.
D
- CONNECTING OF THE MASTER Wi-Fi OS
!
* OBLIGATORY connection for panels with a 120/230V ac blinker output
** OBLIGATORY connection for panels with a 12/24V ac/dc blinker output. ATTENTION: CHECK POLARITY
The connection is compulsory also in those cases where the blinker is not installed in the system.
ATTENTION: Always connect the control panel blinker output to the MASTER Wi-Fi OS card with one of the dedicated terminals, depending on
whether the blinker is 230V or connected to the wires of the J2 connector for 12/24V. If the connection is not made the door will not work and the
buzzer emits 4 sounds indicating that the connection is missing.
!