G
B
20
20
J1
=>
CONNECTOR FOR CONNECTIONS TO THE CONTROL PANEL AND
SAFETY INPUTS
Green wire => safety strip EDGE 2
- If JP2 is set to the LEFT => this output enables the safety
strips stored in 4-5-6 positions.
- If JP2 is set to the RIGHT => this output is not enabled.
Gray wire => contact common COM
Yellow wire => safety strip EDGE 1
- If JP2 is set to the LEFT => this output enables the safety
strips stored in 1-2-3 positions.
- If JP2 is set to the RIGHT => this output enables the safety
strips stored from 1 to 6 positions.
Black wire => photocell PHOT N.C.
White wire =>
terminal for connecting the wire coming from the system control
button N.O.
Brown wire => auto test power feed A-D+ TEST.
J2
=>
CONNECTOR FOR CONNECTIONS TO THE 12/24V ac/dc CONTROL
PANEL AT THE BLINKER OUTPUT (CHECK POLARITY)
Red wire =>
positive (connects to the positive pole of the blinker
output)
Black wire =>
negative (connects to the negative pole of the blinker output)
J4
=>
TERMINALS FOR CONNECTIONS TO THE 120/230V CONTROL
PANEL, AT THE BLINKER OUTPUT
J5
=>
TERMINAL BOARD FOR CONNECTIONS TO OTHER BRANDS OR
RIB CRX CONTROL PANELS
J8
=> TERMINAL FOR CONNECTION TO THE ANTENNA 868,3 MHz
JP1
=>
A/D+ TEST
-
Jumper selection AUTOTEST mode for control panels with AUTOTEST
negative power feed
+/~
Jumper selection AUTOTEST mode for control panels with AUTOTEST
positive/alternate power feed (as RIB control panels)
JP2
=>
If JP2 is set to the LEFT
- EDGE 1 output enables the safety strips stored in 1-2-3 positions
- EDGE 2 output enables the safety strips stored in 4-5-6 positions
If JP2 is set to the RIGHT
- EDGE 1 output enables the safety strips stored from 1 to 6 positions
- EDGE 2 output is not enabled.
WARNING:
after moving the jumper with MASTER Wi-Fi OS powered, press
the S1 button fot 7 times to activate the change of the position of JP2 jumper.
SW1
=> Micro-switches for pairing and identifying strips and photocells
S1
=>
PROG. RX
Programming button
BUZZER
=>
Sound signal for installation, warning and alarm status
LED
DL1 (red)
- strip contact N.C. (EDGE 2)
DL2 (red)
- strip contact N.C. (EDGE 1)
DL3 (red)
- photocell contact N.C. (PHOTO)
DL4 (red)
- total opening command with push-button N.O. in the system
DL5 (green)
- available for future implementations
DL6 (yellow)
- electrical power indicator 12-24V ac/dc
DL7 (dual-color) -
radio code learning for blinker
DUAL-COLOR LED EDGE PHOT
off
=> operating normally
green
=> strip sensor or photocell engaged
red/green
=> alarm
LED EDGE PHOT 1 - EDGE SENSOR OR PHOTOCELL 1
LED EDGE PHOT 2 - EDGE SENSOR OR PHOTOCELL 2
LED EDGE PHOT 3 - EDGE SENSOR OR PHOTOCELL 3
LED EDGE PHOT 4 - EDGE SENSOR OR PHOTOCELL 4
LED EDGE PHOT 5 - EDGE SENSOR OR PHOTOCELL 5
LED EDGE PHOT 6 - EDGE SENSOR OR PHOTOCELL 6
SW1 MICRO-SWITCHES - DIP
DIP 1 ON => STRIP SENSOR OR PHOTOCELL 1 ACTIVATED
DIP 2 ON => STRIP SENSOR OR PHOTOCELL 2 ACTIVATED
DIP 3 ON => STRIP SENSOR OR PHOTOCELL 3 ACTIVATED
DIP 4 ON => STRIP SENSOR OR PHOTOCELL 4 ACTIVATED
DIP 5 ON => STRIP SENSOR OR PHOTOCELL 5 ACTIVATED
DIP 6 ON => STRIP SENSOR OR PHOTOCELL 6 ACTIVATED
ATTENTION:
every time is executed a change of position of dip switches, press
PROG RX push-botton for 6 times to update the system programming. At the end
the dual-color leds EDGE/PHOT must be turn off.
C
- LAYOUT
12/24V ac/dc
J1
JP1
SW1
J5
S1
JP2
J8
J4
J2
Dual-color Led
EDGE PHOT 1-6
BUZZER
4 3 2 1
COM
K.BUTTON
12/24V ac/dc
+
-
2+ 1-
Power feed
12/24V ac/dc
4 3
Total opening
control contact
COM-OPEN/K