24
4.3 PROGRAMMING THE CHAIN RACE
This procedure must be carried out ONLY by the installer and ONLY during the setting up of the system.
For correct programming, before making changes, always return the chain to the high position (see paragraph 4.2).
⚠
With the trimmer in disabled position ( flashing light turned on), the current sensor is excluded.
4.4 ADJUSTMENT OF THE CURRENT SENSOR
This procedure must be carried out ONLY by the installer and ONLY during the setting up of the system.
The movement can be performed in particular situations in which it is not possible to move the chain to the lifted position in automatic mode.
4.5 REGULATION OF THE AUTOMATIC RE-CLOSURE TIME
This procedure must be carried out ONLY by the installer and ONLY during the setting up of the
system.
The movement can be effectuated in particular situations in which it is not possible to move the
chain to the lifted position in automatic mode.
TRIMMER 1 - Raising managed by photocells
TRIMMER 2-> 3 - automatic rise waiting time from 3 s to 180 s
TRIMMER 3 - automatic raising disabled
With the chain in movement, check the sensitivity of
the intervention of the current sensor and check that
there is a regular functioning of the chain.
SW1 POSITION
MAN
AUT
Check that the functioning is regular and that the sensitivity
is setted in a correct way.
Increase lightly the trimmer to balance the frictions which
can vary with the time and the temperature.
Turn the TORQUE STOP trimmer in anti-clockwise
sense to decrease the force of the motors.
It is possible to turn the TORQUE STOP trimmer in
clockwise sense to increase the force of the motors.
Sensitivity too low
Sensitivity too high or
not constant operation
Repeat the
sensitivity check
-
+
MAX
DISABLE
TORQUE STOP
-
+
MAX
DISABLE
TORQUE STOP
DECREASE
OF FORCE
INCREASE
OF FORCE
-
+
MAX
DISABLE
TORQUE STOP
With the chain completely raise
give a relay command and wait
for complete chain lowering.
SW1 POSITION
MAN
AUT
Turn the
AUT. CLOSE TIME
trimmer in clockwise sense.
In this way, the automatic chain raising pause time
is increased.
Turn the
AUT. CLOSE TIME
trimmer anticlockwise
sense.
In this way, the automatic chain raising pause time
is reduced.
The time is too brief
By turning the
AUT. CLOSE TIME
trimmer completely in anticlockwise
sense
(1)
the chain raising is managed by the photocells (after a
few seconds from the photocell contact release, the chain rises).
Turn the
AUT. CLOSE TIME
trimmer completely in clockwise
sense (3) to disable automatic chain raising.
Disabled automatic
chain raising
The time is too long
AUTOMATIC
CHAIN RAISING
DISABLED
-
+
1
2
3
MAX
AUT. CLOSE TIME
-
+
1
2
3
MAX
AUT. CLOSE TIME
INCREASE
OF TIME
-
+
1
2
3
MAX
AUT. CLOSE TIME
DECREASE
OF TIME
When the chain reaches the desired lower position, re-press the
BLUE
button. The chain
stops.
Press the
BLUE
button. The chain begins to lower.
Check the wiring of the motor. Repeat the test.
Check if the chain is completely raised, if
SW1
is on
AUT
and repeat the test.
Re-press the
BLUE
button.
Press the step by step button (terminal blocks 5 and 11). The chain rises to the upper
position.
During the memorization of the race and for the next 2 complete cycles of moving
(lraising) avoid interventions on stop and photocells.
Avoid also the intervention of the current sensor, because the card in these 2 first
movements acquires the parameters for a proper functioning.
Press the step by step button (terminal blocks 5 and 11). The chain lowers completely.
The rising and lowering are stored.
If the chain inverts the movement, bring it back to the upper position (
SW1
to
MAN
and
maintain pushed the
YELLOW
button).
Once the chain is raised, move back the
SW1
to
AUT
and restart from point
A
.
If the chain inverts the movement, bring it back to the upper position (
SW1
to
MAN
and
maintain pushed the
YELLOW
button).
Once the chain is lifted, move back the
SW1
to
AUT
and restart from point
A
To re-program the rising and lowering repeat this procedure from point
A.
SW1 POSITION
MAN
AUT
YES
NO
Press the
BLUE
button for a while.
The flashing signal begins flashing slowly.
NO
NO
YES
YES
YES
YES
NO
NO
YES
G
B
Set the trimmer to
the minimum
A
-
+
1
2
3