20
G
B
TECHNICAL DATA / INSTALLATION STOPPER
LAY-OUT
DESCRIPTION AND DIMENSION OF THE COLUMN
2
3
Chain attachment
ring
1
Description:
1 - STOPPER Chain barrier
2 - Control board
3 - Chain protection guide ACG5481
4 - Chain ACG5480
5 - SUN Radio transmitter
⚠
The value in the table has been determinated using a chain of 400 g/m.
Cable
2 x 2,5 mm
2
Lenght of the chain (m)
4
6
8
10
12
14
16
18
20
Relative height in the middle X (cm)
75
70
65
60
55
50
45
40
35
TECHNICAL DATA
STOPPER
Power supply
230 Vac 50/60 Hz
Absorption
A
1
Motor Power
W
60
Force
Nm
645
Service
%
50
Operating temperature
°C
-20 ÷ +55
Protection Degree
IP
34
Lubrification
Permanent
Weight
kg
25
Max chain weight
kg
8,5