PCB L ayout
2. DedicatedE vent Trigger Inputs 1 to 6
The six inputs haved
edicatedf unc ons
i)
PanelO
pen/CloseE vent
ii)
PanicB
utton
iii)
Burglary Zone #1
iv)
Burglary Zone #2
v)
FireA
larm
vi)
MedicalA
l arm
3. Auxiliary 12V
These terminals provide auxiliary power for the external sounder
that might require 12V power. The auxiliary output is protected by
an autor eset ng fuse (PTC) rateda t 1.1A
mp).
4. Output 1
(Siren)
Output 1 is a high current (1 Amp),
switched nega ve supervised
output
for driving a siren/bell .
The func on can be modified in the
configura on.
5.O
utput 2 (Strobe)
Output 2 is a high current (1 Amp), switched nega ve supervised
output for driving a strobe light.
The func on can be modified in the
configura on.
6. Serial
Port
The serial port
is providedf orl ocal downloading via Rhino
UDL.
7.R
adio Serial Port
The Radio porti s used forc onnec ngt o the serialc onnec on ont he
TX RhinoR
adio Transmitter.
8. ModeB
utton
This button performs several func ons:
a)
If the button
is held pressed during power up the control
will revertt od
efault se ngs.
b)
A er power up, if the buttoni sp
resseda nd held, itw
ill
allow thel earning of a new Remote Control
.
9. Antenna Screw Connector
This
connector provides a screw in connec on for the on
-board
wireless transceiver antenna.
10.S ystem StatusL EDs
Green:
AC power present.
Red:
A Panic had beena c vated .
Yellow:
The Panic Packi si n FOB Learn Mode
.
Orange:
Ba ery
Fault.
11. LED Status
display
Dual
red 7 segment LED display that shows
Panic FOB informa on as
well as system
fault messages.
12. Lid Tamper Connector
This connector can be used to connect a lid tamper switch to
providep
rotec on for when the enclosure coveri so
pened.
13. BatteryC
onnec ons
A 12V rechargeable ba ery must be connected to these two
terminals in order to provide con nuous system opera on in the
event of mains failure. The ba ery output is protected by an auto
rese ng fuse (PTC) rated at 1.6 Amp.
8
9
10
11
12
1
2
3
4
5
6
7
AC Input
1
The two wires from the transformer are connected to these terminals and supply power to the system.
Dedicated Event Trigger Inputs 1 to 6
2
The six inputs are normally open and triggered when they are closed. They have dedicated functions:
i) Panel open/close event
ii) Panic
iii) Burglary zone #1
iv) Burglary zone #2
v) Fire alarm
vi) Medical alarm
Auxillary 12V
3
These terminals provide auxiliary power for the external sounder that might require 12V power. The
auxiliary output is protected by an auto resetting fuse (PTC) rated at 1.1 Amp.
Output 1 (Siren)
4
Output 1 is a high current (1 Amp), switched negative supervised output for driving a siren/bell.
The function can be modified in the configuration.
Output 2 (Strobe)
5
Output 2 is a high current (1 Amp), switched negative supervised output for driving a strobe light.
The function can be modified in the configuration.
Serial Port
6
The serial port is provided for local downloading via Rhino UDL.
8