2, 4, 5, 6 Spare.
Mode Button
7
This button performs several functions:
i) If the button is held pressed during power up, the control will revert to default settings.
ii) After power up, if the button is pressed and held, it will allow the learning of a new remote
control.
Antenna Screw Connector
8
This connector provides a screw in connection for the onboard wireless transceiver antenna.
System Status LEDs
9
Green: AC power present
Red:
Yellow:
Orange: Battery fault
AC panic has been activated
The panic pack is in remote control learn mode
LED Status Display
10
Dual red 7 segment LED display that shows panic remote control information as well as system
fault messages.
Lid Tamper Connector
11
This connector can be used to connect a lid tamper switch to provide protection for when the
enclosure cover is opened.
Battery Connections
12
A 12V rechargeable battery must be connected to these two terminals in order to provide
continuous system operation in the event of a mains failure. The battery output is protected by an
auto resetting fuse (PTC) rated at 1.6 Amp.
Wireless Remote Control
Each user may be assigned a wireless remote control to allow remote control of the system. The
remote control features a multi-colour status LED and internal beeper to provide user feedback
when using the remote. The figure below shows the layout of the remote control:
5
3
1
6
4
2
7
Panic Alarm
1
This button activates the panic alarm.
Stop Panic
3
This button is used to silence the siren.
All other buttons are spare and do not have a function in the Rhino Panic Pack.
7 Activity LED
The activity LED flashes red when the remote control is transmitting a wireless signal and flashes
green for acknowledgment.