Open the door. Insert the BUTTON into the safety switch. The display shows:
1=PROG 2=DATA
3=FREE 4=CLEAN
Make the cleanings of the mixing bowls pressing
button 4
; the display shows:
CLEANINGS
SEL 1-2-3- - - - - - -
Press
buttons 1
,
2
and
3
. With all these three buttons use about 3 litres of water altogether (the button 1
makes the cleaning of the group; the other ones the cleaning of the existing mixing bowls). This will
remove any possible trace of dirt from the boiler. Press the internal key on the display board inside the
machine.
Switch the machine off
.
Wash hands thoroughly.
Prepare separately, in a suitable container, a disinfecting antibacterial solution of chlorine,
according to the instructions enclosed in the chemical.
Lift the cover up.
Remove all the product containers and completely disassemble the containers. Immerse all the parts into
the previously prepared solution. Remove the silicon product outlet pipes and their supports. Immerse
the whole in the solution. With a soaked cloth, clean even the mixer bases that remain fixed to the
machine.
WARNING: The time of permanence in the solution, in order to obtain a full disinfecting, is stated
on the packaging of the chemical
At the end of the disinfecting, recover canisters and covers, dry them very carefully (using
compressed air, a hair dryer or perfectly clean and sterile cloths) and reassemble them in the
machine. Recover all other parts from the solution and put them back in the machine in opposite
sequence with respect to disassembly.
Switch on the machine and wait for the message:
RHEA VENDORS
HORECA LARGE 380
Carry out repeatedly washing cycles of the mixing bowls pushing twice the internal
key
on the display
board inside the machine until is displayed the message:
1=PROG 2=DATA
3=FREE 4=CLEAN
Push
button 4
; the display shows:
CLEANINGS
SEL 1-2-3
Use
buttons 1
,
2
or
3
. Use about 2 litres of water altogether. This will remove all traces of disinfecting
solution from the outlet pipes. Press the
internal
button
on the display board inside the machine.
14.1.3 Regeneration of the water softener filter
This section should be applied only to machines equipped with water softener filter. Follow the
instructions attached to the softener filter in order to compute the filter regenerating frequency and the
execution modality.
15 Machine out of service
15.1 Temporary out of service
Should a long period be foreseen in which the machine will not operate, the following operations must be
carried out: Enter in the programming mode (see section "Enter and exit from the programming mode"):
- by means of
button 1
choose the programming sub-menu:
MAN1260007 V.1 – 18/12/2014