8.3.5
High Cabinet Temperature Alarm -
Occurs when the temperature in
the cabinet rises above 120°F
(48.9°C) for more than ten (10)
seconds.
If this alarm is present for three (3) minutes or more, the Compressor will
SHUTDOWN
to protect against damage due to overheating. Once the
temperature lowers to 112°F (44.4°C) the Compressor will re-start.
See section 13.12 for troubleshooting information.
8.3.6
High Compressor Last Run Time Alarm –
Occurs when the compressor
takes longer to pressurize the air
tank than the set point for the
alarm. (Default setting is 3:00
minutes)
See section 13.17 for troubleshooting information.
8.3.7
Compressor Total Hour Alarm –
Occurs when the compressor has
reached an 8,000-hour
maintenance interval. Perform
the required maintenance.
See section 10.3 for maintenance information.