Radio Frequency Systems
BD1500W Series Air Dryers User’s Guide
Page 55 of 98
100518834 – Rev. B
9.3 Measuring Compressor Voltage
9.3.1
Power the air dryer
OFF
9.3.2
Open Front Panel (section 8.5 ).
9.3.3
Depressurize the air dryer (section 8.5.1 ).
9.3.4
Locate wire #5 at the solid-
state relay and wire #6 on
Control Board.
9.3.5
Lift plastic cover on
Control Board over wire #6.
9.3.6
Power the air dryer ON
9.3.7
Use a Voltmeter to measure
the voltage:
9.3.7.1
Place the probes over
terminals for wire #5
and wire #6.
The voltage should measure:
110 - 125 VAC
for the
BD1500W & BD1500WLP
models
208 - 230 VAC
for the BD1502W & BD1502WLP models
9.3.8
Close plastic cover on Control Board over wire #6.
9.3.9
Close Front Panel.
WARNING!
Extreme care should be exercised to avoid contact with live
electrical circuits.
It is highly recommended that you remove all
jewelry before performing any procedures.
Summary of Contents for BD1500W Series
Page 2: ......