13.16 Compressor Excessive AMP Draw
Possible Cause
Check
Corrective Action
Restriction in air line
Remove Discharge
Hose from Compressor
(hose to the heatless
dryer)
Re-measure
Compressor AMP
Draw
(section 9.2 )
If measurement is
below the
recommended amps,
trace hoses from
Compressor to
Unloader Valve looking
for restrictions or kinks
Compressor failing
Remove Discharge
Hose from Compressor
(hose to the heatless
dryer)
Re-measure
Compressor AMP
Draw
(section 9.2 )
If measurement is still
above the
recommended amps,
replace the Compressor
(section 11.2 )
or send it in for repair
(section 12. )
13.17 High Compressor Last Run Time Alarm
Possible Cause
Check
Corrective Action
Low System Pressure
Verify System Pressure
Adjust System Pressure
High Flow condition
Verify Flow Rate
(
FLOW
) reading is not
higher than expected
Troubleshoot High
Flow condition
(section 13.11 )
Defective Unloader
Valve
Test Unloader Valve
operation (section 9.7 )
If this is continuously
flowing high amounts
Replace Unloader
Valve
(section 11.2 )