8.4.3
Low Outlet Pressure Alarm Set Point
(default setting is 6.5 PSI (44.8 KPa) for W models, 0.30 PSI (2.1 KPa) for
WLP models
8.4.3.1
Press the Right (
)
Arrow Button to access the
Change Value Screen.
8.4.3.2
Press the Right (
) &
Left (
) Arrow Buttons to
move the underscore
beneath the digit to change.
8.4.3.3
Press the Up (
) & Down (
) Arrow Buttons to change the value of
the selected digit.
8.4.3.4
Press the Right (
) Arrow Button until the underscore disappears.
8.4.3.5
Press the Right (
)
Arrow Button until the
underscore appears under
the correct setting (
YES
or
NO
).
8.4.3.6
Press the Up (
) Arrow to confirm. This will lock in the new setting
value.