HN-1010/1510
When a parameter value is changed from the value currently in the HopNet radio, the
parameter label and value will turn red and the Apply Settings button will appear.
When the value is changed back to the value that is currently in the attached HopNet
radio, the label and parameter value will return back to black. When new values are
applied to the HopNet radio, the red values will turn black indicating the updated
values in the radio.
NOTE:The changes are not sent to the HopNet radio until the Apply Settings
button is clicked.
Context sensitive help is available through the F1 key or Help menu.
About the INIT.INI File
One of the files unpacked with the program is the INIT.INI file. It contains the entries
below and an explanation has been included on how each parameter may be used.
ErrorLevel=0
Leave this value as is. Only change it at the request of Cirronet Tech Support.
BiDirectionalHigh=55
BiDirectionalMedium=40
ReceiveHigh=55
ReceiveMedium=40
These parameters change the color levels (in percent) on the RF Tools bar
graphs/pie charts.
RFToolsInterval=1000
This parameter sets the how often bar graphs / pie charts will update (in msec)
RSSIMarginal=-60
RSSIPoor=-80
These parameters set the levels (in dBm) of color the bars on the RSSI bar chart
will display. Above the level set by
RSSIMarginal
, the bars will be green in
color. Between the levels set by
RSSIMarginal
and
RSSIPoor
, the bars will be
yellow in color and below the level set by
RSSIPoor,
the bars will be red in color.
FullShow=0, 1, 2
This changes the number of options that are viewable
0 (default) = Shows minimum amount of options.
1 = Adds all other options.
2 = Adds WinCom.
AutoDetect=1
1 = Auto-detects radio,
0 = User-defined inputs
The parameters below should not be changed as they are specific to different radios.
These parameters will come from the factory set for your radio.
-40dBm=125
-95dBm=55
©
2000- 2004 Cirronet
™
Inc
19
M-2410-0010 Rev A